A Prospective, Randomized Trial of Bioresorbable Polymer Drug-Eluting Stents versus Fully Bioresorbable Scaffolds in Patients Undergoing Coronary Stenting

<b>Background:</b> The performance of an everolimus-eluting bioresorbable scaffold (BRS) was inferior to an everolimus-eluting metallic drug-eluting stent (DES) with permanent polymer, mainly due the mechanical features of BRS technology. The performance of BRS as compared to metallic DES with bioresorbable polymers remains unstudied. <b>Methods:</b> This prospective, randomized, multicenter, clinical trial enrolled patients who underwent coronary stenting for de novo coronary lesions. Patients were randomly assigned to bioresorbable polymer everolimus-eluting stents (BP-EES) or everolimus-eluting BRS. The primary endpoint was percentage diameter stenosis (in-device) at 6- to 8-month angiographic surveillance. The main secondary endpoint was the device-oriented composite endpoint (DOCE) of cardiac death/target vessel-myocardial infarction/target lesion revascularization assessed after 12 months and 5 years. <b>Results:</b> The trial was prematurely terminated after the enrollment of 117 of 230 patients (BP-EES, n = 60; BRS, n = 57) due to safety issues associated with BRS technology. The primary endpoint of in-device diameter stenosis at angiographic surveillance was 12.5 ± 7.7% with BP-EES versus 19.3 ± 16.5% with BRS (<i>p</i> = 0.01). The DOCE occurred in 5.0% in the BP-EES group versus 12.3% of patients in the BRS group (hazard ratio [HR] 2.48, 95% confidence interval [CI] 0.64-9.58, <i>p</i> = 0.19) after 12 months and in 11.7% in the BP-EES group versus 26.4% of patients in the BRS group (HR 2.38, 95% CI 0.97-5.84, <i>p</i> = 0.06) after 5 years. <b>Conclusions:</b> BP-EES showed superior mid-term angiographic performance compared with BRS. Clinical event rates did not differ significantly between the groups up to 5 years of follow-up. These results should be interpreted with caution in view of the premature discontinuation of the study.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-10-07
DOI
https://doi.org/10.3390/jcm13195949
Citations
1
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Prospective, Randomized Trial of Bioresorbable Polymer Drug-Eluting Stents versus Fully Bioresorbable Scaffolds in Patients Undergoing Coronary Stenting

Sebastian Kufner, Heribert Schunkert, Thorsten Kessler, Petra Hoppmann et al.
1 citations
Journal of Clinical Medicine
Coronary Interventions and Diagnostics
0.57
article

A Prospective, Randomized Trial of Bioresorbable Polymer Drug-Eluting Stents versus Fully Bioresorbable Scaffolds in Patients Undergoing Coronary Stenting

Sebastian Kufner, Heribert Schunkert, Thorsten Kessler, Petra Hoppmann, Karl‐Ludwig Laugwitz, Jens Wiebe, Constantin Kuna, Christian Bradaric, Salvatore Cassese, Michael Joner, Erion Xhepa, Robert A. Byrne, Mathieu Pfleiderer, Adnan Kastrati
article en
1 citations

Abstract

<b>Background:</b> The performance of an everolimus-eluting bioresorbable scaffold (BRS) was inferior to an everolimus-eluting metallic drug-eluting stent (DES) with permanent polymer, mainly due the mechanical features of BRS technology. The performance of BRS as compared to metallic DES with bioresorbable polymers remains unstudied. <b>Methods:</b> This prospective, randomized, multicenter, clinical trial enrolled patients who underwent coronary stenting for de novo coronary lesions. Patients were randomly assigned to bioresorbable polymer everolimus-eluting stents (BP-EES) or everolimus-eluting BRS. The primary endpoint was percentage diameter stenosis (in-device) at 6- to 8-month angiographic surveillance. The main secondary endpoint was the device-oriented composite endpoint (DOCE) of cardiac death/target vessel-myocardial infarction/target lesion revascularization assessed after 12 months and 5 years. <b>Results:</b> The trial was prematurely terminated after the enrollment of 117 of 230 patients (BP-EES, n = 60; BRS, n = 57) due to safety issues associated with BRS technology. The primary endpoint of in-device diameter stenosis at angiographic surveillance was 12.5 ± 7.7% with BP-EES versus 19.3 ± 16.5% with BRS (<i>p</i> = 0.01). The DOCE occurred in 5.0% in the BP-EES group versus 12.3% of patients in the BRS group (hazard ratio [HR] 2.48, 95% confidence interval [CI] 0.64-9.58, <i>p</i> = 0.19) after 12 months and in 11.7% in the BP-EES group versus 26.4% of patients in the BRS group (HR 2.38, 95% CI 0.97-5.84, <i>p</i> = 0.06) after 5 years. <b>Conclusions:</b> BP-EES showed superior mid-term angiographic performance compared with BRS. Clinical event rates did not differ significantly between the groups up to 5 years of follow-up. These results should be interpreted with caution in view of the premature discontinuation of the study.

Journal of Clinical MedicineVol. 13(19)
TUM Klinikum (DE), Mater Misericordiae University Hospital (IE), German Centre for Cardiovascular Research (DE), Deutsches Herzzentrum München (DE), Technical University of Munich (DE)
Good health and well-being
Openalex Percentile: Top 29%
Coronary Interventions and Diagnostics
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.