Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator's light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium-tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. The neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-10-01
DOI
https://doi.org/10.1063/5.0219573
Citations
2
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
1.32

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

V. Yu. Glebov, C. Stöeckl, S. P. Regan, C. J. Forrest et al.
2 citations
Review of Scientific Instruments
Laser-Plasma Interactions and Diagnostics
1.32
article

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

V. Yu. Glebov, C. Stöeckl, S. P. Regan, C. J. Forrest, M. J. Rosenberg, J. P. Knauer, J.S. Martínez
article en
2 citations

Abstract

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator's light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium-tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. The neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

Review of Scientific InstrumentsVol. 95(10)
Energetics (United States) (US), University of Rochester (US)
U.S. Department of Energy
Affordable and clean energy
Openalex Percentile: Top 11%
Laser-Plasma Interactions and Diagnostics
1.32
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.