Interfacial bond strength of SCFST composite columns after freeze-thaw cycles

This paper investigates the effect of freeze-thaw cycles (FTCs) on the interfacial bond strength of square concrete-filled steel tube (SCFST) composite columns through push-out tests on specimens subjected to FTCs. Key factors considered include the number of FTCs, the wall thickness of the square steel tube, and the interface length. By quantitatively analyzing components of interfacial bonding , the mechanisms underlying the reduction in bond stress after FTCs were elucidated. Results showed that interface concrete in specimens after FTCs exhibited more severe fracture failure under load. As the number of FTCs increased, there was a notable decline in bond failure load, interfacial bond strength, and slip values. Increasing the wall thickness of the steel tube mitigated the effects of FTCs on interfacial bond strength by stabilizing temperature fluctuations of the interfacial concrete and reducing the formation of frost cracks. Furthermore, extending the interface length exacerbated the impact of FTCs on chemical bonding force, yet it mitigated the effect of FTCs on overall bonding performance. Considering changes in bond stress after FTCs under various design parameters, three correlation coefficients were introduced, leading to precise formulas for calculating the interfacial bond stress of SCFST composite columns after FTCs. The calculation results showed that the maximum error did not exceed 6 %. Additionally, the critical shear transfer length of SCFST composite columns after FTCs was determined based on calculated results. These findings provide important recommendations for the safe application of SCFST composite columns in cold regions. • The bonding properties of SCFST after FTCs were studied. • The whole process was analyzed from the microscopic point of view. 3.The formula for calculating bond stress was presented.

Authors

Publication Details

Journal
Journal of Constructional Steel Research
Published
2024-10-07
DOI
https://doi.org/10.1016/j.jcsr.2024.109067
Citations
8
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
2.09

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interfacial bond strength of SCFST composite columns after freeze-thaw cycles

Mengdi Huang, PingJun Chen, Junhua Li, Weichen Wang et al.
8 citations
Journal of Constructional Steel Research
Structural Load-Bearing Analysis
2.09
article

Interfacial bond strength of SCFST composite columns after freeze-thaw cycles

Mengdi Huang, PingJun Chen, Junhua Li, Weichen Wang, Jiaxing Ma
article en
8 citations

Abstract

This paper investigates the effect of freeze-thaw cycles (FTCs) on the interfacial bond strength of square concrete-filled steel tube (SCFST) composite columns through push-out tests on specimens subjected to FTCs. Key factors considered include the number of FTCs, the wall thickness of the square steel tube, and the interface length. By quantitatively analyzing components of interfacial bonding , the mechanisms underlying the reduction in bond stress after FTCs were elucidated. Results showed that interface concrete in specimens after FTCs exhibited more severe fracture failure under load. As the number of FTCs increased, there was a notable decline in bond failure load, interfacial bond strength, and slip values. Increasing the wall thickness of the steel tube mitigated the effects of FTCs on interfacial bond strength by stabilizing temperature fluctuations of the interfacial concrete and reducing the formation of frost cracks. Furthermore, extending the interface length exacerbated the impact of FTCs on chemical bonding force, yet it mitigated the effect of FTCs on overall bonding performance. Considering changes in bond stress after FTCs under various design parameters, three correlation coefficients were introduced, leading to precise formulas for calculating the interfacial bond stress of SCFST composite columns after FTCs. The calculation results showed that the maximum error did not exceed 6 %. Additionally, the critical shear transfer length of SCFST composite columns after FTCs was determined based on calculated results. These findings provide important recommendations for the safe application of SCFST composite columns in cold regions. • The bonding properties of SCFST after FTCs were studied. • The whole process was analyzed from the microscopic point of view. 3.The formula for calculating bond stress was presented.

Journal of Constructional Steel ResearchVol. 223
National Natural Science Foundation of China
Climate action
Openalex Percentile: Top 14%
Structural Load-Bearing Analysis
2.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Interfacial bond strength of SCFST composite columns after freeze-thaw cycles — Mengdi Huang, PingJun Chen, et al. · Journal of Constructional Steel Research (2024) | TGRS Research Map | TGRS