Electrodeposition of Gold Nanoparticles for a Highly Sensitive Immunosensor for White Spot Syndrome Virus (WSSV) Envelope Protein VP28 Detection Based on Electrochemical Impedance Spectroscopy Technique
Lacking effective treatment, white spot syndrome virus (WSSV) causes mass mortality in farmed shrimp, significantly damaging the shrimp industry worldwide. To enable early detection and diagnosis of this disease, we have demonstrated an electrochemical immunosensor to detect the VP28 antigen, a key envelope protein of this virus. First, gold nanoparticles (AuNPs) were electrodeposited on the sensor’s carbon surface to enhance both its sensitivity and its capability to form a self-assembled monolayer (SAM). Subsequently, an SAM using 11-Mercaptoundecanoic acid was coated as an intermediary layer for immobilizing VP28 antibodies. The specific interaction of VP28 antigen-antibody, confirmed by Western Blot, impeded electrons transfer, leading to an increase in charge transfer resistance. Cyclic voltammetry (CV) was utilized to deposit AuNPs and combined with electrochemical impedance spectroscopy (EIS) to characterize the modification of the sensor’s electrode surface through changes in electric current and impedance. The scanning electron microscope (SEM) results showed that nanosized gold particles were uniformly dispersed on the carbon electrode surface. Electric measurement results showed that the change in charge transfer resistance (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta {R}_{\text {CT}}$ </tex-math></inline-formula>) correlates linearly with the VP28 protein concentration range from 0 to 60 ng/mL, with an <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${R}^{\,{2}}$ </tex-math></inline-formula> coefficient of 0.98945 and a low limit of detection (LOD) of 2.38 ng/mL. Additionally, the anode peak current decreased from 15.150 to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$7.725~\mu $ </tex-math></inline-formula>A with increasing antigen concentration. Control experiments with various proteins demonstrated the specificity of the proposed immunosensor for detecting VP28. This sensor offers an accessible electrochemical sensing tool, enabling convenient, direct, and immediate diagnosis of WSSV on shrimp farms.
Authors
- Nguyễn Đăng Phú (ORCID: https://orcid.org/0000-0001-5306-7055)
- Linh Huynh Thi Thuy (ORCID: https://orcid.org/0009-0006-7568-8454)
- J.‐C. Chiao (ORCID: https://orcid.org/0000-0001-9670-0340)
- Tung Thanh Bui (ORCID: https://orcid.org/0000-0003-4628-059X)
- Hung Cao (ORCID: https://orcid.org/0000-0003-4197-7208)
- Loc Do Quang
- Trinh Chu Duc (ORCID: https://orcid.org/0000-0003-2323-8217)
- Chun‐Ping Jen (ORCID: https://orcid.org/0000-0001-5558-5817)
- Hung Anh Nguyen (ORCID: https://orcid.org/0000-0002-7527-3383)
Institutions
- National Chung Cheng University (TW)
- Vietnam National University, Hanoi (VN)
- Southern Methodist University (US)
- University of California, Irvine (US)
- Hue University (VN)
Publication Details
- Journal
- IEEE Sensors Journal
- Published
- 2024-10-07
- DOI
- https://doi.org/10.1109/jsen.2024.3468318
- Citations
- 1
- Primary Topic
- Studies on Chitinases and Chitosanases
- Type
- article
- Field-Weighted Citation Impact
- 0.23
Funders
- Đại học Huế