Ultrasensitive Rapid Antigen Test by Geometric Lateral Flow Assays and Highly Doped Upconversion Nanoparticles

The paper-based lateral flow assay (LFA) testing strips are currently the most widely used for point-of-care testing (POCT), valued for their rapid result turnaround times in a few minutes. However, their sensitivity has been limited. Upconversion nanoparticles (UCNPs), especially highly doped ones, have emerged as promising luminescent reporters to enhance the LFA sensitivity. These UCNPs exhibit a nonlinear enhancement in luminescence with excitation power density, necessitating higher power densities for higher brightness. In this study, we utilized a geometric paper strip design to minimize the immune reaction area and maximize the excitation power density, enabling ultrasensitive detection of the SARS-CoV-2 nucleoprotein antigen. This design also slowed the antigen flow on the paper strip, extending the reaction time between antigen and antibody, thereby enhancing the efficiency of the immune reaction. Through this design, our approach achieved over a 100-fold enhancement in the limit of detection (LOD) compared with the widely used LFAs, based on gold colloidal nanoparticles and europium nanoparticles. This innovation expands the scope of LFA applications that require a low LOD.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-10-07
DOI
https://doi.org/10.1021/acs.analchem.4c02379
Citations
19
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
3.50

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasensitive Rapid Antigen Test by Geometric Lateral Flow Assays and Highly Doped Upconversion Nanoparticles

Yuan Liu, Jawairia Umar Khan, Mahnaz Maddahfar, Le Zhang et al.
19 citations
Analytical Chemistry
Biosensors and Analytical Detection
3.50
article

Ultrasensitive Rapid Antigen Test by Geometric Lateral Flow Assays and Highly Doped Upconversion Nanoparticles

Yuan Liu, Jawairia Umar Khan, Mahnaz Maddahfar, Le Zhang, Jiajia Zhou, Dayong Jin, Shihui Wen
article en
19 citations

Abstract

The paper-based lateral flow assay (LFA) testing strips are currently the most widely used for point-of-care testing (POCT), valued for their rapid result turnaround times in a few minutes. However, their sensitivity has been limited. Upconversion nanoparticles (UCNPs), especially highly doped ones, have emerged as promising luminescent reporters to enhance the LFA sensitivity. These UCNPs exhibit a nonlinear enhancement in luminescence with excitation power density, necessitating higher power densities for higher brightness. In this study, we utilized a geometric paper strip design to minimize the immune reaction area and maximize the excitation power density, enabling ultrasensitive detection of the SARS-CoV-2 nucleoprotein antigen. This design also slowed the antigen flow on the paper strip, extending the reaction time between antigen and antibody, thereby enhancing the efficiency of the immune reaction. Through this design, our approach achieved over a 100-fold enhancement in the limit of detection (LOD) compared with the widely used LFAs, based on gold colloidal nanoparticles and europium nanoparticles. This innovation expands the scope of LFA applications that require a low LOD.

Analytical ChemistryVol. 96(42)
University of Technology Sydney (AU)
Australian Research Council, National Health and Medical Research Council
Openalex Percentile: Top 7%
Biosensors and Analytical Detection
3.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.