A novel colonoscope with an extra-wide field of view increases polyp detection rate compared with standard colonoscope: Prospective model-based trial

<b>Background and study aims</b> Colonoscopy, the gold standard for early detection of colorectal cancer, may miss polyps especially those hidden behind folds. This prospective study compared polyp detection and performance of a novel colonoscope with extra-wide field of view (EFOV) of 230 degrees (partially retrograde) to a standard colonoscope (SC, 170 degrees) in a colon model. <b>Patients and methods</b> A 3D printed colon model was used featuring 12 polyps placed throughout different colon segments, with several located on the proximal side of haustral folds. Endoscopists were instructed to identify polyps, first inserting the SC immediately followed by the EFOV device, and to place a snare to simulate a polypectomy. A standardized survey was used to record operator impressions. <b>Results</b> Twenty-nine experienced endoscopists participated in this study. On average, 5.3 vs 9.6 polyps were detected with the standard and EFOV colonoscopes, respectively ( <i>P</i> < 0.001). Five of 29 operators (17.2%) detected all 12 polyps with the EFOV device, whereas no operator detected all polyps with the SC. The success rate for snare placement was 100% for both endoscopes with similar times (mean of 14 vs 15 seconds for SC and EFOV, respectively). EFOV handling and optical performance were rated as equally good or better by all endoscopists. <b>Conclusions</b> Use of a colonoscope with novel optics significantly improved polyp detection compared with a standard colonoscope in this non-randomized model-based study, with favorable performance and usability ratings for the EFOV instrument. Clinical studies are needed to confirm these encouraging preliminary results.

Authors

Institutions

Publication Details

Journal
Endoscopy International Open
Published
2024-10-01
DOI
https://doi.org/10.1055/a-2422-9502
Citations
3
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
0.85
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel colonoscope with an extra-wide field of view increases polyp detection rate compared with standard colonoscope: Prospective model-based trial

Horst Neuhaus, Arthur Schmidt, T Nowak
3 citations
Endoscopy International Open
Colorectal Cancer Screening and Detection
0.85
article

A novel colonoscope with an extra-wide field of view increases polyp detection rate compared with standard colonoscope: Prospective model-based trial

Horst Neuhaus, Arthur Schmidt, T Nowak
article en
3 citations

Abstract

<b>Background and study aims</b> Colonoscopy, the gold standard for early detection of colorectal cancer, may miss polyps especially those hidden behind folds. This prospective study compared polyp detection and performance of a novel colonoscope with extra-wide field of view (EFOV) of 230 degrees (partially retrograde) to a standard colonoscope (SC, 170 degrees) in a colon model. <b>Patients and methods</b> A 3D printed colon model was used featuring 12 polyps placed throughout different colon segments, with several located on the proximal side of haustral folds. Endoscopists were instructed to identify polyps, first inserting the SC immediately followed by the EFOV device, and to place a snare to simulate a polypectomy. A standardized survey was used to record operator impressions. <b>Results</b> Twenty-nine experienced endoscopists participated in this study. On average, 5.3 vs 9.6 polyps were detected with the standard and EFOV colonoscopes, respectively ( <i>P</i> < 0.001). Five of 29 operators (17.2%) detected all 12 polyps with the EFOV device, whereas no operator detected all polyps with the SC. The success rate for snare placement was 100% for both endoscopes with similar times (mean of 14 vs 15 seconds for SC and EFOV, respectively). EFOV handling and optical performance were rated as equally good or better by all endoscopists. <b>Conclusions</b> Use of a colonoscope with novel optics significantly improved polyp detection compared with a standard colonoscope in this non-randomized model-based study, with favorable performance and usability ratings for the EFOV instrument. Clinical studies are needed to confirm these encouraging preliminary results.

Endoscopy International OpenVol. 12(10)
Robert Bosch Hospital (DE)
Good health and well-being
Openalex Percentile: Top 22%
Colorectal Cancer Screening and Detection
0.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A novel colonoscope with an extra-wide field of view increases polyp detection rate compared with standard colonoscope: Prospective model-based trial — Horst Neuhaus, Arthur Schmidt, et al. · Endoscopy International Open (2024) | TGRS Research Map | TGRS