A Reconfigurable IPT System With CC‐CV Output Characteristics and High Misalignment Tolerance

ABSTRACT Misalignment between transmission coils is an inevitable challenge in inductive power transfer (IPT) systems, particularly affecting the constant current (CC) and constant voltage (CV) outputs essential for battery charging. A reconfigurable IPT system with high misalignment tolerance and CC‐CV output characteristics is proposed in this article. The main circuit of the system is composed of a LCC‐LCC and LCC‐S topology with two intermediate coils, and two switches equipped with single unidirectionally blocking MOSFETs are incorporated on the secondary side to transition from CC to CV mode. A comprehensive analysis of the output characteristics for the proposed hybrid topology in both CC and CV modes is provided. Furthermore, the parameter optimization design based on BP coil for wide misalignment tolerance is presented. The experimental results demonstrate that the proposed reconfigurable IPT system can maintain stable CC and CV outputs within 50% lateral and vertical offset (the coupling factor varies from 0.1 to 0.21), when the load varies from 11 to 80 Ω, and the output current and voltage fluctuations remain below 5%.

Authors

Institutions

Publication Details

Journal
International Journal of Circuit Theory and Applications
Published
2024-10-07
DOI
https://doi.org/10.1002/cta.4311
Citations
1
Primary Topic
Wireless Power Transfer Systems
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Reconfigurable IPT System With CC‐CV Output Characteristics and High Misalignment Tolerance

Ningchao Zhang, Yongsheng Fu, Man Zhao, Zhaowei Gong et al.
1 citations
International Journal of Circuit Theory and Applications
Wireless Power Transfer Systems
0.21
article

A Reconfigurable IPT System With CC‐CV Output Characteristics and High Misalignment Tolerance

Ningchao Zhang, Yongsheng Fu, Man Zhao, Zhaowei Gong, Yajing Yang
article en
1 citations

Abstract

ABSTRACT Misalignment between transmission coils is an inevitable challenge in inductive power transfer (IPT) systems, particularly affecting the constant current (CC) and constant voltage (CV) outputs essential for battery charging. A reconfigurable IPT system with high misalignment tolerance and CC‐CV output characteristics is proposed in this article. The main circuit of the system is composed of a LCC‐LCC and LCC‐S topology with two intermediate coils, and two switches equipped with single unidirectionally blocking MOSFETs are incorporated on the secondary side to transition from CC to CV mode. A comprehensive analysis of the output characteristics for the proposed hybrid topology in both CC and CV modes is provided. Furthermore, the parameter optimization design based on BP coil for wide misalignment tolerance is presented. The experimental results demonstrate that the proposed reconfigurable IPT system can maintain stable CC and CV outputs within 50% lateral and vertical offset (the coupling factor varies from 0.1 to 0.21), when the load varies from 11 to 80 Ω, and the output current and voltage fluctuations remain below 5%.

International Journal of Circuit Theory and ApplicationsVol. 53(6)
Xi'an Technological University (CN)
Affordable and clean energy
Openalex Percentile: Top 47%
Wireless Power Transfer Systems
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Reconfigurable IPT System With CC‐CV Output Characteristics and High Misalignment Tolerance — Ningchao Zhang, Yongsheng Fu, et al. · International Journal of Circuit Theory and Applications (2024) | TGRS Research Map | TGRS