An Extra-High Voltage Test System for Transmission Expansion Planning Studies Considering Single Contingency Conditions

This paper presents an extra-high voltage synthetic test system that consists of 500 kV and 765 kV voltage levels, specifically designed for transmission expansion planning (TEP) studies. The test network includes long transmission lines whose series impedance and shunt admittance are calculated using the equivalent π circuit model, accurately reflecting the distributed nature of the line parameters. The proposed test system offers technically feasible steady-state operation under normal and all single contingency conditions. By incorporating accurate modeling for long transmission lines and EHV voltage levels, the test system provides a realistic platform for validating models and theories prior to their application in actual power systems. It supports testing new algorithms, control strategies, and grid management techniques, aids in transmission expansion planning and investment decisions, and facilitates comprehensive grid evaluations. Moreover, a TEP study is conducted on this test system and various scenarios are evaluated and compared economically.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2024-10-05
DOI
https://doi.org/10.3390/electronics13193937
Citations
8
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
1.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Extra-High Voltage Test System for Transmission Expansion Planning Studies Considering Single Contingency Conditions

Mona Ghassemi, Bhuban Dhamala
8 citations
Electronics
HVDC Systems and Fault Protection
1.67
article

An Extra-High Voltage Test System for Transmission Expansion Planning Studies Considering Single Contingency Conditions

Mona Ghassemi, Bhuban Dhamala
article en
8 citations

Abstract

This paper presents an extra-high voltage synthetic test system that consists of 500 kV and 765 kV voltage levels, specifically designed for transmission expansion planning (TEP) studies. The test network includes long transmission lines whose series impedance and shunt admittance are calculated using the equivalent π circuit model, accurately reflecting the distributed nature of the line parameters. The proposed test system offers technically feasible steady-state operation under normal and all single contingency conditions. By incorporating accurate modeling for long transmission lines and EHV voltage levels, the test system provides a realistic platform for validating models and theories prior to their application in actual power systems. It supports testing new algorithms, control strategies, and grid management techniques, aids in transmission expansion planning and investment decisions, and facilitates comprehensive grid evaluations. Moreover, a TEP study is conducted on this test system and various scenarios are evaluated and compared economically.

ElectronicsVol. 13(19)
The University of Texas at Dallas (US)
National Science Foundation
Industry, innovation and infrastructure
Openalex Percentile: Top 15%
HVDC Systems and Fault Protection
1.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Extra-High Voltage Test System for Transmission Expansion Planning Studies Considering Single Contingency Conditions — Mona Ghassemi, Bhuban Dhamala · Electronics (2024) | TGRS Research Map | TGRS