Optimization of Cooling Fan Based on Unequal Angle and Leading-Edge Triangle Blade Design
In order to reduce the noise of the axial fan, an uneven blade spacing was used to optimize tonal noise and blade leading edge triangles were added to optimize the broadband noise. First, different angular distribution schemes were designed on the basis of ensuring the dynamic balance of the fan, and the noise of the different schemes was simulated by using the computational aeroacoustics (CAA) numerical simulation method. Then, the best optimal angular distribution design was selected for experimental verification, which confirmed the reliability of the numerical calculation. The test results also show that the uneven blade spacing has little effect on the fan pressure and efficiency. Additionally, triangular leading edges were added to each blade based on the uneven blade spacing design. Combining these two optimization schemes proved to reduce the fan noise by 13.4 dBA.
Authors
- Feng Jiang (ORCID: https://orcid.org/0000-0003-0239-259X)
- Xie Youfu
Publication Details
- Journal
- The International Journal of Acoustics and Vibration
- Published
- 2024-09-30
- DOI
- https://doi.org/10.20855/ijav.2024.29.32048
- Primary Topic
- Heat Transfer Mechanisms
- Type
- article
- Field-Weighted Citation Impact
- 0.00