Sensor technology advancement enhancing exhaled breath portability: Device set up and pilot test in the longitudinal study of lung cancer

User-friendliness of exhaled breath sampling procedure and portability of the collected samples are strategic key-points for disease monitoring in unstructured environments. These issues have been addressed by collecting exhaled breath on adsorbing cartridges; many samplers on cartridge have been used in clinical experiments through exhalate collection, including our patented Pneumopipe (European patent 12425057.2). Increasing the operative functionality of the sampling device enhances collection effectiveness and the representativity of the specimen. These features become of paramount importance when a minimal amount of disease needs to be detected with preventive approach in screening and follow-up. The primary endpoint was aimed at achieving Pneumopipe optimization (Pneumopipe II). The secondary endpoint was to investigate through a pilot longitudinal study focused on monitoring recurrence after lung cancer surgical resection and the evolution of the breath fingerprint before and after surgery. A quartz crystal-based gas sensor array, named BIONOTE-V was used to measure the breath fingerprint. Cross-validated Partial Least Square Discriminant Analysis and Principal component analysis were used to study the time evolution of the breath fingerprint before and after surgery. Thirty-five patients had the breath fingerprint collected before and after surgery, with fifteen having at least two more measurements for each timepoint (at least two before and two after surgery). (Primary endpoint) At isoprene lab tests, Pneumopipe has shown to preserve its effectiveness in collecting volatile mixture in a representative sample. (Secondary endpoint) Cancer recurrence was observed in 8 patients. Postoperative breath fingerprint detected lung cancer recurrence with an accuracy of 91%, a sensitivity of 75%, a specificity of 96%, a PPV of 86% and a NPV of 93%. Effectiveness of exhalate collection and portability of the sampler are preserved with Pneumopipe II. • User-friendliness of exhaled breath sampling procedure and portability of the collected samples are strategic key-points for disease monitoring in unstructured environments. • Pneumopipe is a patented solution for exhaled breath collection with a standard and reproducible method. • Increasing the operative functionality of the sampling device enhances collection effectiveness and the representativity of the specimen, thus, the primary endpoint was aimed at achieving Pneumopipe optimization. • The secondary endpoint was to investigate through a pilot longitudinal study focused on monitoring recurrence after lung cancer surgical resection and the evolution of the breath fingerprint before and after surgery. • At isoprene lab tests, Pneumopipe has shown to preserve its effectiveness in collecting volatile mixture in a representative sample. • Postoperative breath fingerprint detected lung cancer recurrence with an accuracy of 91%, a sensitivity of 75%, a specificity of 96%, a PPV of 86% and a NPV of 93%.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2024-10-06
DOI
https://doi.org/10.1016/j.snb.2024.136735
Citations
4
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensor technology advancement enhancing exhaled breath portability: Device set up and pilot test in the longitudinal study of lung cancer

Panaiotis Finamore, Gaetano Rocco, Alessandro Zompanti, Anna Sabatini et al.
4 citations
Sensors and Actuators B Chemical
Advanced Chemical Sensor Technologies
0.74
article

Sensor technology advancement enhancing exhaled breath portability: Device set up and pilot test in the longitudinal study of lung cancer

Panaiotis Finamore, Gaetano Rocco, Alessandro Zompanti, Anna Sabatini, Marco Santonico, Simone Grasso, Raffaele Antonelli Incalzi, Costanza Cenerini, Luca Frasca, Filippo Longo, Giorgio Pennazza, Pierfilippo Crucitti, Federica Celoro, Ludovica La Monica
article en
4 citations

Abstract

User-friendliness of exhaled breath sampling procedure and portability of the collected samples are strategic key-points for disease monitoring in unstructured environments. These issues have been addressed by collecting exhaled breath on adsorbing cartridges; many samplers on cartridge have been used in clinical experiments through exhalate collection, including our patented Pneumopipe (European patent 12425057.2). Increasing the operative functionality of the sampling device enhances collection effectiveness and the representativity of the specimen. These features become of paramount importance when a minimal amount of disease needs to be detected with preventive approach in screening and follow-up. The primary endpoint was aimed at achieving Pneumopipe optimization (Pneumopipe II). The secondary endpoint was to investigate through a pilot longitudinal study focused on monitoring recurrence after lung cancer surgical resection and the evolution of the breath fingerprint before and after surgery. A quartz crystal-based gas sensor array, named BIONOTE-V was used to measure the breath fingerprint. Cross-validated Partial Least Square Discriminant Analysis and Principal component analysis were used to study the time evolution of the breath fingerprint before and after surgery. Thirty-five patients had the breath fingerprint collected before and after surgery, with fifteen having at least two more measurements for each timepoint (at least two before and two after surgery). (Primary endpoint) At isoprene lab tests, Pneumopipe has shown to preserve its effectiveness in collecting volatile mixture in a representative sample. (Secondary endpoint) Cancer recurrence was observed in 8 patients. Postoperative breath fingerprint detected lung cancer recurrence with an accuracy of 91%, a sensitivity of 75%, a specificity of 96%, a PPV of 86% and a NPV of 93%. Effectiveness of exhalate collection and portability of the sampler are preserved with Pneumopipe II. • User-friendliness of exhaled breath sampling procedure and portability of the collected samples are strategic key-points for disease monitoring in unstructured environments. • Pneumopipe is a patented solution for exhaled breath collection with a standard and reproducible method. • Increasing the operative functionality of the sampling device enhances collection effectiveness and the representativity of the specimen, thus, the primary endpoint was aimed at achieving Pneumopipe optimization. • The secondary endpoint was to investigate through a pilot longitudinal study focused on monitoring recurrence after lung cancer surgical resection and the evolution of the breath fingerprint before and after surgery. • At isoprene lab tests, Pneumopipe has shown to preserve its effectiveness in collecting volatile mixture in a representative sample. • Postoperative breath fingerprint detected lung cancer recurrence with an accuracy of 91%, a sensitivity of 75%, a specificity of 96%, a PPV of 86% and a NPV of 93%.

Sensors and Actuators B ChemicalVol. 423
Memorial Sloan Kettering Cancer Center (US), Università Campus Bio-Medico (IT)
European Commission, Ministero della Salute, Associazione Italiana per la Ricerca sul Cancro, Fiona and Stanley Druckenmiller Center for Lung Cancer Research
Good health and well-being
Openalex Percentile: Top 32%
Advanced Chemical Sensor Technologies
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.