In vial thin-film solid-phase microextraction using silver nanoparticles as coating for the determination of phenols in waters

• A novel TF-SPME device based on vials coated with silver nanoparticles. • The optimum in-vial device has 2 layers of AgNPs prepared at pH 11. • The in-vial device was highly efficient towards phenols. • A quite simple and greener method succeed with environmental waters. A novel thin-film solid-phase microextraction (TF-SPME) device based on glass vials internally coated with silver nanoparticles (AgNPs) was developed for the first time, and used for determining five phenols in wastewater, bottled water, and irrigation water samples by high-performance liquid chromatography coupled to a photodiode array detector (HPLC-PDA). Different AgNPs were synthesized varying the ratio of metallic salt versus the reduction agent, and the pH of the synthesis. The preparation of the TF-SPME glass vial device was optimized in terms of the type of AgNPs used and the number of layers of AgNPs. Besides, the TF-SPME procedure was also optimized. The TF-SPME method was very simple, only requiring the addition of 18 mL of water and 5 min of agitation, followed by the disposal of the water and addition of the 750 µL as desorption solvent, and direct HPLC-PDA injection. The entire method showed adequate analytical performance, with limits of detection ranging from 3 to 8 μg·L -1 , and intra-day and inter-day precision (as RSD), both evaluated with different vials and therefore showing inter-batch precision, with values between 8.70 and 16.4%, and 6.0 and 19.7%, respectively. The TF-SPME-HPLC-PDA procedure was compared with previous methods for the determination of phenols, both in terms of analytical performance and greenness assessments applying different metrics, showing clear advantages.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography Open
Published
2024-10-06
DOI
https://doi.org/10.1016/j.jcoa.2024.100182
Citations
7
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
1.65

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vial thin-film solid-phase microextraction using silver nanoparticles as coating for the determination of phenols in waters

Adrián Gutiérrez‐Serpa, Verónica Pino, Ana I. Jiménez‐Abizanda, Alejandro Rodríguez-González
7 citations
Journal of Chromatography Open
Analytical chemistry methods development
1.65
article

In vial thin-film solid-phase microextraction using silver nanoparticles as coating for the determination of phenols in waters

Adrián Gutiérrez‐Serpa, Verónica Pino, Ana I. Jiménez‐Abizanda, Alejandro Rodríguez-González
article en
7 citations

Abstract

• A novel TF-SPME device based on vials coated with silver nanoparticles. • The optimum in-vial device has 2 layers of AgNPs prepared at pH 11. • The in-vial device was highly efficient towards phenols. • A quite simple and greener method succeed with environmental waters. A novel thin-film solid-phase microextraction (TF-SPME) device based on glass vials internally coated with silver nanoparticles (AgNPs) was developed for the first time, and used for determining five phenols in wastewater, bottled water, and irrigation water samples by high-performance liquid chromatography coupled to a photodiode array detector (HPLC-PDA). Different AgNPs were synthesized varying the ratio of metallic salt versus the reduction agent, and the pH of the synthesis. The preparation of the TF-SPME glass vial device was optimized in terms of the type of AgNPs used and the number of layers of AgNPs. Besides, the TF-SPME procedure was also optimized. The TF-SPME method was very simple, only requiring the addition of 18 mL of water and 5 min of agitation, followed by the disposal of the water and addition of the 750 µL as desorption solvent, and direct HPLC-PDA injection. The entire method showed adequate analytical performance, with limits of detection ranging from 3 to 8 μg·L -1 , and intra-day and inter-day precision (as RSD), both evaluated with different vials and therefore showing inter-batch precision, with values between 8.70 and 16.4%, and 6.0 and 19.7%, respectively. The TF-SPME-HPLC-PDA procedure was compared with previous methods for the determination of phenols, both in terms of analytical performance and greenness assessments applying different metrics, showing clear advantages.

Journal of Chromatography OpenVol. 6
Universidad de La Laguna (ES), Hospital Universitario de Canarias (ES), Centro de Investigación Biomédica en Red (ES)
“la Caixa” Foundation, Ministerio de Ciencia e Innovación, Agencia Canaria de Investigación, Innovación y Sociedad de la Información
Clean water and sanitation
Openalex Percentile: Top 18%
Analytical chemistry methods development
1.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.