Microchip gas chromatographic columns dedicated for space exploration: Stationary phase coating, setup optimization and evaluation of column performances

• Microcolumns with removable capillary junctions were coated for space exploration • The manifold and connections were optimized to limit extra-column volumes • Column efficiency was increased by 100 % using a reduced coating velocity • The best microcolumn efficiency was more than 45,000 theoretical plates • Coating efficiencies of square cross-section and cylindrical columns were compared This work is the first part of a project aiming to specifically design gas chromatographic microcolumns for space exploration. In particular, this study explored the functionalization and characterization of silicon/glass microchip gas chromatographic columns designed with a serpentine-shaped channel having an internal square cross-section. This microcolumn can be connected using a robust fluidic manifold with removable capillary connections to a conventional gas chromatograph or implemented in a prototype instrument for space exploration. First, benchtop gas chromatographic system was optimized in terms of injector liner volume, internal diameter (I.D.) of the capillary connections and data frequency of detection to ensure an optimal evaluation of column efficiency. Junction capillaries of 100 μm I.D., a liner of 1.2 mm I.D. and a detection acquisition frequency of 100 Hz were found to be the optimal set-up and parameters. Moreover, the stationary phase coating velocity was slowed-down to increase column efficiency by 100 %. Then, the performances of a square cross-section capillary column were compared with those of a conventional circular cross-section column. The coating efficiencies were estimated at 55 % and 42 % for circular and square internal cross-section geometries respectively, demonstrating that the square section geometry did not affect significantly the column performances. Stationary phase films of different thicknesses, from 0.032 to 0.260 µm, were coated on different microchips of the same production batch to assess the influence of film thickness on the chromatographic performances. Microchips performance was evaluated through Golay's plots, and some of the microchips were also studied by optical microscopy. The efficiency and retention capacity of our microchip column is shown to be highly dependent on the film thickness (9,000 plates.m -1 with k = 0.12 for the thinnest film and up to almost 4,000 plates.m -1 with k = 0.93 for the thickest film). Finally, the coating process repeatability was validated by producing three identical microchips with RSD of 4.8% for the average number of theoretical plates.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography Open
Published
2024-10-05
DOI
https://doi.org/10.1016/j.jcoa.2024.100180
Citations
2
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.48

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microchip gas chromatographic columns dedicated for space exploration: Stationary phase coating, setup optimization and evaluation of column performances

Valérie Peulon‐Agasse, Guillaume Rioland, Arnaud Philippart, Pascal Cardinaël et al.
2 citations
Journal of Chromatography Open
Analytical Chemistry and Chromatography
0.48
article

Microchip gas chromatographic columns dedicated for space exploration: Stationary phase coating, setup optimization and evaluation of column performances

Valérie Peulon‐Agasse, Guillaume Rioland, Arnaud Philippart, Pascal Cardinaël, Cyril Szopa, Malak Rizk-Bigourd, A. Buch, Audrey Boco-Simon, Gabin Bergerot
article en
2 citations

Abstract

• Microcolumns with removable capillary junctions were coated for space exploration • The manifold and connections were optimized to limit extra-column volumes • Column efficiency was increased by 100 % using a reduced coating velocity • The best microcolumn efficiency was more than 45,000 theoretical plates • Coating efficiencies of square cross-section and cylindrical columns were compared This work is the first part of a project aiming to specifically design gas chromatographic microcolumns for space exploration. In particular, this study explored the functionalization and characterization of silicon/glass microchip gas chromatographic columns designed with a serpentine-shaped channel having an internal square cross-section. This microcolumn can be connected using a robust fluidic manifold with removable capillary connections to a conventional gas chromatograph or implemented in a prototype instrument for space exploration. First, benchtop gas chromatographic system was optimized in terms of injector liner volume, internal diameter (I.D.) of the capillary connections and data frequency of detection to ensure an optimal evaluation of column efficiency. Junction capillaries of 100 μm I.D., a liner of 1.2 mm I.D. and a detection acquisition frequency of 100 Hz were found to be the optimal set-up and parameters. Moreover, the stationary phase coating velocity was slowed-down to increase column efficiency by 100 %. Then, the performances of a square cross-section capillary column were compared with those of a conventional circular cross-section column. The coating efficiencies were estimated at 55 % and 42 % for circular and square internal cross-section geometries respectively, demonstrating that the square section geometry did not affect significantly the column performances. Stationary phase films of different thicknesses, from 0.032 to 0.260 µm, were coated on different microchips of the same production batch to assess the influence of film thickness on the chromatographic performances. Microchips performance was evaluated through Golay's plots, and some of the microchips were also studied by optical microscopy. The efficiency and retention capacity of our microchip column is shown to be highly dependent on the film thickness (9,000 plates.m -1 with k = 0.12 for the thinnest film and up to almost 4,000 plates.m -1 with k = 0.93 for the thickest film). Finally, the coating process repeatability was validated by producing three identical microchips with RSD of 4.8% for the average number of theoretical plates.

Journal of Chromatography OpenVol. 6
Centre National de la Recherche Scientifique (FR), Université de Versailles Saint-Quentin-en-Yvelines (FR), Université Paris-Saclay (FR), Centre National d'Études Spatiales (FR), Sorbonne Université (FR), Normandie Université (FR), CentraleSupélec (FR), Institut Pierre-Simon Laplace (FR), Laboratoire atmosphères, milieux, observations spatiales (FR), Université de Rouen Normandie (FR)
Centre National d’Etudes Spatiales, Université de Rouen, Région Normandie
Openalex Percentile: Top 40%
Analytical Chemistry and Chromatography
0.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.