Efficacy of balloon angioplasty and stent placement in the treatment of central venous stenosis in patients with chronic kidney disease on hemodialysis

Background: Central venous stenosis is a common complication in hemodialysis patients, often caused by multiple long-term catheter use. This retrospective observational study evaluated the efficacy of balloon angioplasty and stent placement in treating central venous stenosis secondary to hemodialysis catheter use. Methods: A retrospective observational study was conducted at the Hospital General de México Dr. Eduardo Liceaga, analyzing clinical records of 16 chronic kidney disease patients diagnosed with central venous stenosis who underwent endovascular surgery between January 2022 and August 2024. The study evaluated demographic characteristics, comorbidities, stenosis location, and technical success. Statistical analysis included descriptive measures, Shapiro-Wilk test for normality, and paired Student's t-test (α=0.05) to compare pre- and post-angioplasty venous diameters. Results: The mean age of patients was 44.6±13.5 years, with a slight female predominance. The most common stenosis location was the right subclavian vein (31.2%), followed by the left brachiocephalic trunk (25%). Pre-procedure stenotic vessel diameter averaged 3.86±1.5 mm, increasing to 9.19±2.03 mm post-procedure. Statistical analysis showed a significant 138% increase in vessel diameter (p<0.001). Of the 16 procedures, 11 patients underwent successful angioplasty, with 37.5% requiring stent placement due to recoil greater than 30%. In 5 cases, crossing the occlusive lesion was not possible. Conclusions: The study demonstrated the effectiveness of balloon angioplasty and stent placement in treating central venous stenosis, with a statistically significant improvement in vascular diameter. However, further studies with long-term follow-up are needed to evaluate the durability of these results and optimize management of complex cases.

Authors

Institutions

Publication Details

Journal
International Surgery Journal
Published
2024-10-04
DOI
https://doi.org/10.18203/2349-2902.isj20242986
Citations
1
Primary Topic
Renal and Vascular Pathologies
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy of balloon angioplasty and stent placement in the treatment of central venous stenosis in patients with chronic kidney disease on hemodialysis

Miguel Á. Sierra-Juárez, Alan I. Valderrama-Treviño, Marlon E. Lacayo Valenzuela, Fernando G. Ramírez Estrada
1 citations
International Surgery Journal
Renal and Vascular Pathologies
0.42
article

Efficacy of balloon angioplasty and stent placement in the treatment of central venous stenosis in patients with chronic kidney disease on hemodialysis

Miguel Á. Sierra-Juárez, Alan I. Valderrama-Treviño, Marlon E. Lacayo Valenzuela, Fernando G. Ramírez Estrada
article en
1 citations

Abstract

Background: Central venous stenosis is a common complication in hemodialysis patients, often caused by multiple long-term catheter use. This retrospective observational study evaluated the efficacy of balloon angioplasty and stent placement in treating central venous stenosis secondary to hemodialysis catheter use. Methods: A retrospective observational study was conducted at the Hospital General de México Dr. Eduardo Liceaga, analyzing clinical records of 16 chronic kidney disease patients diagnosed with central venous stenosis who underwent endovascular surgery between January 2022 and August 2024. The study evaluated demographic characteristics, comorbidities, stenosis location, and technical success. Statistical analysis included descriptive measures, Shapiro-Wilk test for normality, and paired Student's t-test (α=0.05) to compare pre- and post-angioplasty venous diameters. Results: The mean age of patients was 44.6±13.5 years, with a slight female predominance. The most common stenosis location was the right subclavian vein (31.2%), followed by the left brachiocephalic trunk (25%). Pre-procedure stenotic vessel diameter averaged 3.86±1.5 mm, increasing to 9.19±2.03 mm post-procedure. Statistical analysis showed a significant 138% increase in vessel diameter (p<0.001). Of the 16 procedures, 11 patients underwent successful angioplasty, with 37.5% requiring stent placement due to recoil greater than 30%. In 5 cases, crossing the occlusive lesion was not possible. Conclusions: The study demonstrated the effectiveness of balloon angioplasty and stent placement in treating central venous stenosis, with a statistically significant improvement in vascular diameter. However, further studies with long-term follow-up are needed to evaluate the durability of these results and optimize management of complex cases.

International Surgery JournalVol. 11(11)
Hospital General de México (MX)
Good health and well-being
Openalex Percentile: Top 32%
Renal and Vascular Pathologies
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.