Improvement of thermal environment in the outdoor atrium by employing the spray system

Outdoor atriums have recently been applied with increasing frequency for natural illumination, but they produce a harsh thermal environment easily in summer. Moreover, overheating of the outdoor atrium necessitates air-conditioning to moderate indoor thermal comfort. Simultaneously, the substantial heat emissions from air-conditioning outdoor units worsen the outdoor thermal environment, creating a vicious cycle. Traditional passive evaporative methods involving water and greenery, while capable of regulating the thermal environment, suffer from low evaporative efficiency and pose significant challenges. To improve thermal environment in outdoor atriums, the spray system was employed due to its high cooling efficiency, especially in open or semi-open spaces. In this study, a comparative experiment was conducted to evaluate the effectiveness of using a spray system for evaporative cooling in open outdoor spaces. Furthermore, employing high-efficiency evaporative cooling through spraying to disrupt the vicious cycle of indoor and outdoor thermal environments. The dual goals include regulating indoor and outdoor thermal conditions while also mitigating the local heat island effect. Temperature and humidity distribution within the atrium and adjacent hallways were monitored, along with the impact on air-conditioning operation consumption in neighboring offices. Results showed that the spray system significantly improved the thermal environment in the outdoor atrium, reducing the average and peak air temperatures by 0.94-2.83 °C and 2.92-5.21 °C, respectively. It also resulted in a drop in the average temperature by 0.56-1.62 °C and the peak temperature by 2.31-3.25 °C in adjacent hallways. This effectively eased the issue of overheating in these areas while raising the comfort level in adjacent office spaces. The predicted mean vote decreased from 1.46 to 0.87, indicating a significant improvement in thermal environment in neighboring offices. Furthermore, the daily energy consumption was reduced by 10.6-12.4% in neighboring offices. This study provided the valuable guidance for improving thermal environments within outdoor atrium.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-05
DOI
https://doi.org/10.1038/s41598-024-74128-7
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvement of thermal environment in the outdoor atrium by employing the spray system

Nan Ding, Xi Meng, Feng Pang, Jingyu Su
1 links
Scientific Reports
Building Energy and Comfort Optimization
article

Improvement of thermal environment in the outdoor atrium by employing the spray system

Nan Ding, Xi Meng, Feng Pang, Jingyu Su
article en

Abstract

Outdoor atriums have recently been applied with increasing frequency for natural illumination, but they produce a harsh thermal environment easily in summer. Moreover, overheating of the outdoor atrium necessitates air-conditioning to moderate indoor thermal comfort. Simultaneously, the substantial heat emissions from air-conditioning outdoor units worsen the outdoor thermal environment, creating a vicious cycle. Traditional passive evaporative methods involving water and greenery, while capable of regulating the thermal environment, suffer from low evaporative efficiency and pose significant challenges. To improve thermal environment in outdoor atriums, the spray system was employed due to its high cooling efficiency, especially in open or semi-open spaces. In this study, a comparative experiment was conducted to evaluate the effectiveness of using a spray system for evaporative cooling in open outdoor spaces. Furthermore, employing high-efficiency evaporative cooling through spraying to disrupt the vicious cycle of indoor and outdoor thermal environments. The dual goals include regulating indoor and outdoor thermal conditions while also mitigating the local heat island effect. Temperature and humidity distribution within the atrium and adjacent hallways were monitored, along with the impact on air-conditioning operation consumption in neighboring offices. Results showed that the spray system significantly improved the thermal environment in the outdoor atrium, reducing the average and peak air temperatures by 0.94-2.83 °C and 2.92-5.21 °C, respectively. It also resulted in a drop in the average temperature by 0.56-1.62 °C and the peak temperature by 2.31-3.25 °C in adjacent hallways. This effectively eased the issue of overheating in these areas while raising the comfort level in adjacent office spaces. The predicted mean vote decreased from 1.46 to 0.87, indicating a significant improvement in thermal environment in neighboring offices. Furthermore, the daily energy consumption was reduced by 10.6-12.4% in neighboring offices. This study provided the valuable guidance for improving thermal environments within outdoor atrium.

Scientific ReportsVol. 14(1)
Qingdao University (CN), Qingdao University of Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 82%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.