Investigation Of Strength Development In Conventional And High Strength Concrete Under Different Curing Conditions

The composite material obtained by blending cement, aggregate, water and, when necessary, an additive, placing a mixture with carefully adjusted proportions into molds of the desired shape and size without gaps and hardening under appropriate maintenance conditions, is called concrete or traditional concrete. In the 1960s, concretes with compressive strengths of 41 MPa and 52 MPa were used on the market in the USA. In the recent past, concretes with compressive strengths varying between 80 MPa and 100 MPa have been commercially applied in structures made with in-situ concrete and prestressed concrete structural elements. Strength developments of traditional and high-strength concretes under different curing conditions will be examined. For this purpose, central pressure tests were carried out on cube samples produced. For concrete production; For each aggregate class, cement, saturation water, mixed water and high strength concretes; It was prepared by weighing silica fume and superplasticizer. The prepared samples were stored in standard or cold water for 3 days, 7 days, 28 days and 90 days. In this study, the strength development of traditional and high-strength concretes under different curing conditions was examined experimentally. In accordance with the experimental work plan determined for this investigation, concrete cube samples were produced and these samples were subjected to the central pressure test. The concretes produced are in C55, C20 and C12 classes. As a result, although similar behaviors were observed in high-strength and conventional concretes cured in different environments, it was determined that the difference in curing temperature was more effective on the strength development than the inadequacy of curing in water. It should be noted here that it would be beneficial to conduct similar studies on different types of concrete.

Authors

Institutions

Publication Details

Journal
Türkiye teknoloji ve uygulamalı bilimler dergisi.
Published
2024-10-05
DOI
https://doi.org/10.70562/tubid.1501310
Primary Topic
Concrete and Cement Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation Of Strength Development In Conventional And High Strength Concrete Under Different Curing Conditions

Yakup Murat Çebi
Türkiye teknoloji ve uygulamalı bilimler dergisi.
Concrete and Cement Materials Research
article

Investigation Of Strength Development In Conventional And High Strength Concrete Under Different Curing Conditions

Yakup Murat Çebi
article en

Abstract

The composite material obtained by blending cement, aggregate, water and, when necessary, an additive, placing a mixture with carefully adjusted proportions into molds of the desired shape and size without gaps and hardening under appropriate maintenance conditions, is called concrete or traditional concrete. In the 1960s, concretes with compressive strengths of 41 MPa and 52 MPa were used on the market in the USA. In the recent past, concretes with compressive strengths varying between 80 MPa and 100 MPa have been commercially applied in structures made with in-situ concrete and prestressed concrete structural elements. Strength developments of traditional and high-strength concretes under different curing conditions will be examined. For this purpose, central pressure tests were carried out on cube samples produced. For concrete production; For each aggregate class, cement, saturation water, mixed water and high strength concretes; It was prepared by weighing silica fume and superplasticizer. The prepared samples were stored in standard or cold water for 3 days, 7 days, 28 days and 90 days. In this study, the strength development of traditional and high-strength concretes under different curing conditions was examined experimentally. In accordance with the experimental work plan determined for this investigation, concrete cube samples were produced and these samples were subjected to the central pressure test. The concretes produced are in C55, C20 and C12 classes. As a result, although similar behaviors were observed in high-strength and conventional concretes cured in different environments, it was determined that the difference in curing temperature was more effective on the strength development than the inadequacy of curing in water. It should be noted here that it would be beneficial to conduct similar studies on different types of concrete.

Türkiye teknoloji ve uygulamalı bilimler dergisi.Vol. 5(2)
Bitlis Eren University (TR)
Sustainable cities and communities
Openalex Percentile: Top 81%
Concrete and Cement Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation Of Strength Development In Conventional And High Strength Concrete Under Different Curing Conditions — Yakup Murat Çebi · Türkiye teknoloji ve uygulamalı bilimler dergisi. (2024) | TGRS Research Map | TGRS