Maximum Isokinetic Eccentric Elbow Flexor Muscle Force Can Be Estimated Using Maximum Isometric Contraction Force

Purpose It is difficult to measure maximal isokinetic eccentric (ECC) muscle strength in the sports field. This study aimed to investigate whether elbow isometric (ISO) flexion muscle strength or muscle thickness (MT) can be used to estimate elbow ECC flexion muscle strength. Material and methods Maximal muscle strength and muscle thickness (MT) were measured in the elbow flexor muscle group of 147 healthy adults (age: 21.3±0.8 years, height: 167.3±8.6 cm, body mass: 61.4±10.6 kg: 99 males and 48 females). Both isometric contraction (ISO) and eccentric contraction (ECC) of elbow flexion muscle strength were measured using an isokinetic dynamometer. The ultrasound measured MT at 50% of the distance from the upper arm to the lateral epicondyle. We performed the multiple regression analysis with elbow ECC flexion muscle strength as the dependent variable and gender, age, height, body mass, elbow ISO flexion muscle strength, and MT as the independent variables. Results Multiple regression analysis revealed a coefficient of determination R<sup>2</sup> value of 0.89 and an adjusted R<sup>2</sup> value of 0.89 (p<0.01). In addition, the independent variables elbow ISO flexor strength (p<0.01, standardized coefficient β=0.94; p<0.01, standardized coefficient β=0.89) and muscle thickness (p<0.05, standardized coefficient β=0.07) were identified as significantly associated factors. Conclusions The results suggest that it is possible to estimate elbow ECC flexion muscle strength using only elbow ISO flexion muscle strength and that ECC flexion muscle strength can be estimated more accurately by adding muscle thickness of the elbow flexor muscle group.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-10-05
DOI
https://doi.org/10.7759/cureus.70878
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Maximum Isokinetic Eccentric Elbow Flexor Muscle Force Can Be Estimated Using Maximum Isometric Contraction Force

Riku Yoshida, Kazuki Kasahara, Y. Murakami, Masatoshi Nakamura
Cureus
Muscle activation and electromyography studies
article

Maximum Isokinetic Eccentric Elbow Flexor Muscle Force Can Be Estimated Using Maximum Isometric Contraction Force

Riku Yoshida, Kazuki Kasahara, Y. Murakami, Masatoshi Nakamura
article en

Abstract

Purpose It is difficult to measure maximal isokinetic eccentric (ECC) muscle strength in the sports field. This study aimed to investigate whether elbow isometric (ISO) flexion muscle strength or muscle thickness (MT) can be used to estimate elbow ECC flexion muscle strength. Material and methods Maximal muscle strength and muscle thickness (MT) were measured in the elbow flexor muscle group of 147 healthy adults (age: 21.3±0.8 years, height: 167.3±8.6 cm, body mass: 61.4±10.6 kg: 99 males and 48 females). Both isometric contraction (ISO) and eccentric contraction (ECC) of elbow flexion muscle strength were measured using an isokinetic dynamometer. The ultrasound measured MT at 50% of the distance from the upper arm to the lateral epicondyle. We performed the multiple regression analysis with elbow ECC flexion muscle strength as the dependent variable and gender, age, height, body mass, elbow ISO flexion muscle strength, and MT as the independent variables. Results Multiple regression analysis revealed a coefficient of determination R<sup>2</sup> value of 0.89 and an adjusted R<sup>2</sup> value of 0.89 (p<0.01). In addition, the independent variables elbow ISO flexor strength (p<0.01, standardized coefficient β=0.94; p<0.01, standardized coefficient β=0.89) and muscle thickness (p<0.05, standardized coefficient β=0.07) were identified as significantly associated factors. Conclusions The results suggest that it is possible to estimate elbow ECC flexion muscle strength using only elbow ISO flexion muscle strength and that ECC flexion muscle strength can be estimated more accurately by adding muscle thickness of the elbow flexor muscle group.

CureusVol. 16(10)
Nishikyushu University (JP), Niigata University of Rehabilitation (JP), Niigata University of Health and Welfare (JP)
Openalex Percentile: Top 84%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.