8226 A Diagnostic Challenge: Factitious Hypobicarbonatemia in Severe Hypertriglyceridemia

Abstract Disclosure: U. Rafat: None. S. Azmat: None. M. Siddiqui: None. R. Alshantti: None. D. Kircheva: None. V. Trendafilova: None. Background: Serum CO2 levels measured by a chemistry analyzer usually correlate with calculated bicarbonate levels on an ABG. There are some instances however, when this is not the case. Severe hypertriglyceridemia can cause serum bicarbonate levels to appear falsely low on metabolic panel. Clinical Case: A 48-year-old man was referred to Endocrinology Clinic for evaluation of hypogonadism and severe hypertriglyceridemia. Routine labs revealed a plasma CO2 of 11 mmol/L (20-31). Na was 133 mmol/L (136-145), K was 4.4 mmol/L (3.5-4.7), Chloride was 101 mmol/L (98-109) and anion gap was 25 (8-20) measured using a Siemens Vista enzymatic chemistry analyzer. His triglycerides were > 1100 mg/dL (0-150), above upper detection limits of the analyzer. The patient reported fatigue and mild abdominal pain. He was admitted to the hospital for further evaluation. His lipase was 41 U/L (12-73), lactic acid 1.2 mmol/L (0.50-2.20). ABG showed pH of 7.41, HCO3 of 26.6 mmol/L (22-29), and anion gap of 7 (10-20). The patient was well-appearing with normal vital signs and normal physical exam. He was made NPO and started on pravastatin, fenofibrate and fish oil. Once his triglycerides were < 1000 mg/dL, he was started on a very low-fat, low-carbohydrate diet. The CO2 level on BMP normalized on day 3 of hospitalization, when triglycerides measured 1010 mg/dL. No other treatment was given for the low CO2 levels. It does not appear that other lab indices were significantly affected by the hypertriglyceridemia. Review of Literature: A BMP measures serum total carbon dioxide using a chemistry analyzer using either an enzymatic/spectro-photometric method, or an electrode-based method; an ABG sample calculates plasma bicarbonate with the Henderson-Hasselbach equation, using the pH and partial pressure of pCO2 in the sample. Enzymatic analyzers measure CO2 using spectrophotometry and decrease in light absorbance is proportional to the sample’s CO2 levels. It is postulated that severely high triglycerides can interfere with this reaction and cause spuriously low CO2 levels, a phenomenon called pseudohypobicarbonatemia. One proposed mechanism for interference with the enzymatic assay method is turbidity causing a falsely low measured CO2 level. Verghese et al found that the severity of the CO2 measurement error positively correlates with the severity of triglyceride elevation. Conclusion: Awareness of the phenomenon of hypertriglyceridemia-induced pseudohypobicarbonatemia can prevent misdiagnosis or delays in diagnosis, as well as unwarranted testing and treatment. Presentation: 6/3/2024

Authors

Institutions

Publication Details

Journal
Journal of the Endocrine Society
Published
2024-10-01
DOI
https://doi.org/10.1210/jendso/bvae163.543
Primary Topic
Lipid metabolism and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

8226 A Diagnostic Challenge: Factitious Hypobicarbonatemia in Severe Hypertriglyceridemia

Diana Kircheva, Victoria Trendafilova, Raeda Alshantti, Mahrukh Siddiqui et al.
Journal of the Endocrine Society
Lipid metabolism and disorders
article

8226 A Diagnostic Challenge: Factitious Hypobicarbonatemia in Severe Hypertriglyceridemia

Diana Kircheva, Victoria Trendafilova, Raeda Alshantti, Mahrukh Siddiqui, Ummara Rafat, Shazia Azmat
article en

Abstract

Abstract Disclosure: U. Rafat: None. S. Azmat: None. M. Siddiqui: None. R. Alshantti: None. D. Kircheva: None. V. Trendafilova: None. Background: Serum CO2 levels measured by a chemistry analyzer usually correlate with calculated bicarbonate levels on an ABG. There are some instances however, when this is not the case. Severe hypertriglyceridemia can cause serum bicarbonate levels to appear falsely low on metabolic panel. Clinical Case: A 48-year-old man was referred to Endocrinology Clinic for evaluation of hypogonadism and severe hypertriglyceridemia. Routine labs revealed a plasma CO2 of 11 mmol/L (20-31). Na was 133 mmol/L (136-145), K was 4.4 mmol/L (3.5-4.7), Chloride was 101 mmol/L (98-109) and anion gap was 25 (8-20) measured using a Siemens Vista enzymatic chemistry analyzer. His triglycerides were > 1100 mg/dL (0-150), above upper detection limits of the analyzer. The patient reported fatigue and mild abdominal pain. He was admitted to the hospital for further evaluation. His lipase was 41 U/L (12-73), lactic acid 1.2 mmol/L (0.50-2.20). ABG showed pH of 7.41, HCO3 of 26.6 mmol/L (22-29), and anion gap of 7 (10-20). The patient was well-appearing with normal vital signs and normal physical exam. He was made NPO and started on pravastatin, fenofibrate and fish oil. Once his triglycerides were < 1000 mg/dL, he was started on a very low-fat, low-carbohydrate diet. The CO2 level on BMP normalized on day 3 of hospitalization, when triglycerides measured 1010 mg/dL. No other treatment was given for the low CO2 levels. It does not appear that other lab indices were significantly affected by the hypertriglyceridemia. Review of Literature: A BMP measures serum total carbon dioxide using a chemistry analyzer using either an enzymatic/spectro-photometric method, or an electrode-based method; an ABG sample calculates plasma bicarbonate with the Henderson-Hasselbach equation, using the pH and partial pressure of pCO2 in the sample. Enzymatic analyzers measure CO2 using spectrophotometry and decrease in light absorbance is proportional to the sample’s CO2 levels. It is postulated that severely high triglycerides can interfere with this reaction and cause spuriously low CO2 levels, a phenomenon called pseudohypobicarbonatemia. One proposed mechanism for interference with the enzymatic assay method is turbidity causing a falsely low measured CO2 level. Verghese et al found that the severity of the CO2 measurement error positively correlates with the severity of triglyceride elevation. Conclusion: Awareness of the phenomenon of hypertriglyceridemia-induced pseudohypobicarbonatemia can prevent misdiagnosis or delays in diagnosis, as well as unwarranted testing and treatment. Presentation: 6/3/2024

Journal of the Endocrine SocietyVol. 8(Supplement_1)
Rosalind Franklin University of Medicine and Science (US), Captain James A. Lovell Federal Health Care Center (US)
Life below water
Openalex Percentile: Top 70%
Lipid metabolism and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.