8654 Real-World Performance Of The Medtronic Extended Infusion Set In The United States

Abstract Disclosure: T. Kwa: Employee; Self; Medtronic Minimed. G. Zhang: Employee; Self; Medtronic Minimed. J. Kiehl: Employee; Self; Medtronic Minimed. V. Putcha: Employee; Self; Medtronic Minimed. A. Patel: Employee; Self; Medtronic Minimed. S. Chattaraj: Employee; Self; Medtronic Minimed. O. Cohen: Employee; Self; Medtronic Minimed. R.A. Vigersky: Employee; Self; Medtronic Minimed. Real-World Performance of the Medtronic Extended Infusion Set in the United States Objective: The Medtronic extended infusion set (EIS) is the first and only infusion set approved for up to 7-day use and its pivotal trial established clinical safety and efficacy.[1] The purpose of this retrospective analysis was to assess real-world EIS performance and overall glycemic outcomes based on United States (US) data uploaded by MiniMed™ 770G system (MM770G) users at an aggregate level. Methods: Infusion set occlusion alarm events and time in (TIR, 70-180 mg/dL), below (TBR, <70 mg/dL) and above (TAR, >180 mg/dL) range of EIS-MM770G users (N=393) with >30-day device use in the U.S. were analyzed and compared against the data of a cohort of the same median age of 50 years (N=77219) using the MM770G with a standard 2/3-day infusion set (at an aggregate level). Results: EIS users experienced a lower occlusion alarm rate (median 0.011 alerts/patient day) compared to 0.016 alerts/patient day with the standard set (p = 0.005). TIR for EIS users was 69.4%, which was numerically greater than the 69.1% for standard set users (p = 0.258). While TAR was not significantly different (28.9% for EIS and 29.0% for standard set, p = 0.995), TBR was significantly lower (0.5% for EIS and 1.3% for standard set, p = 0.000). The difference in the total daily dose (TDD) of insulin between the two groups (53.0 units for EIS, 49.4 units for standard set) was not statistically significant (p = 0.961). Conclusion: Since the U.S. launch, the EIS has continued to perform similarly to the pivotal trial results and an early real-world analysis of EIS use outside of the US.2 The decreased burden of fewer set changes comes with a lower occlusion alarm rate and does not compromise time spent in target range. References: 1.Brazg R, et al. Diabetes Technol Ther. 2022;24:535-543. 2.Kwa T, et al. Diabetes. 2023;72(Supplement_1):910-P. Presentation: 6/1/2024

Authors

Institutions

Publication Details

Journal
Journal of the Endocrine Society
Published
2024-10-01
DOI
https://doi.org/10.1210/jendso/bvae163.906
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

8654 Real-World Performance Of The Medtronic Extended Infusion Set In The United States

Robert Alan Vigersky, Anuj Patel, Ohad Cohen, SARNATH CHATTARAJ et al.
1 citations
Journal of the Endocrine Society
Cardiac Valve Diseases and Treatments
0.40
article

8654 Real-World Performance Of The Medtronic Extended Infusion Set In The United States

Robert Alan Vigersky, Anuj Patel, Ohad Cohen, SARNATH CHATTARAJ, GINA ZHANG, Timothy Kwa, Justin Kiehl, VENKAT PUTCHA
article en
1 citations

Abstract

Abstract Disclosure: T. Kwa: Employee; Self; Medtronic Minimed. G. Zhang: Employee; Self; Medtronic Minimed. J. Kiehl: Employee; Self; Medtronic Minimed. V. Putcha: Employee; Self; Medtronic Minimed. A. Patel: Employee; Self; Medtronic Minimed. S. Chattaraj: Employee; Self; Medtronic Minimed. O. Cohen: Employee; Self; Medtronic Minimed. R.A. Vigersky: Employee; Self; Medtronic Minimed. Real-World Performance of the Medtronic Extended Infusion Set in the United States Objective: The Medtronic extended infusion set (EIS) is the first and only infusion set approved for up to 7-day use and its pivotal trial established clinical safety and efficacy.[1] The purpose of this retrospective analysis was to assess real-world EIS performance and overall glycemic outcomes based on United States (US) data uploaded by MiniMed™ 770G system (MM770G) users at an aggregate level. Methods: Infusion set occlusion alarm events and time in (TIR, 70-180 mg/dL), below (TBR, <70 mg/dL) and above (TAR, >180 mg/dL) range of EIS-MM770G users (N=393) with >30-day device use in the U.S. were analyzed and compared against the data of a cohort of the same median age of 50 years (N=77219) using the MM770G with a standard 2/3-day infusion set (at an aggregate level). Results: EIS users experienced a lower occlusion alarm rate (median 0.011 alerts/patient day) compared to 0.016 alerts/patient day with the standard set (p = 0.005). TIR for EIS users was 69.4%, which was numerically greater than the 69.1% for standard set users (p = 0.258). While TAR was not significantly different (28.9% for EIS and 29.0% for standard set, p = 0.995), TBR was significantly lower (0.5% for EIS and 1.3% for standard set, p = 0.000). The difference in the total daily dose (TDD) of insulin between the two groups (53.0 units for EIS, 49.4 units for standard set) was not statistically significant (p = 0.961). Conclusion: Since the U.S. launch, the EIS has continued to perform similarly to the pivotal trial results and an early real-world analysis of EIS use outside of the US.2 The decreased burden of fewer set changes comes with a lower occlusion alarm rate and does not compromise time spent in target range. References: 1.Brazg R, et al. Diabetes Technol Ther. 2022;24:535-543. 2.Kwa T, et al. Diabetes. 2023;72(Supplement_1):910-P. Presentation: 6/1/2024

Journal of the Endocrine SocietyVol. 8(Supplement_1)
Medtronic (United States) (US)
Openalex Percentile: Top 32%
Cardiac Valve Diseases and Treatments
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.