Effects of Attachment Design and Aligner Material on Mandibular Canine Distal Bodily Movement in Aligner Treatment

Abstract Purpose Dental crowding is a result of a mismatch between tooth size and arch dimensions, which leads to malocclusion; treatment often involves premolar extraction before orthodontic alignment. Clear aligners are limited in their ability to achieve canine distal bodily movement, a common orthodontic maneuver. This study investigated the impacts of attachment design and aligner material on the efficacy of canine distal bodily movement. Methods A finite element analysis was conducted to examine the impact of various attachment designs and two aligner materials, thermoplastic polyurethanes/polycarbonate (TPU/PC) and polyethylene terephthalate glycol-modified (PETG), on mandibular canine distal bodily movement. The investigation focused on the biomechanical responses in the periodontal ligament (PDL) and surrounding alveolar bone. Results Attachment configuration exerted a strong influence on mandibular canine movement. Vertically oriented attachment pairs positioned mesially (mesial occlusal–mesial cervical) resulted in the most effective canine distal bodily movement, followed by a rectangular attachment. TPU/PC aligners induced slightly higher principal stresses in the PDL and von Mises stress and strain in the surrounding alveolar bone compared with PETG aligners; however, the difference was negligible, amounting to less than 6%. Conclusion Attachment design, specifically vertically oriented pairs positioned mesially (mesial occlusal–mesial cervical), was determined to be the crucial factor influencing the efficacy of canine distal bodily movement. The choice of aligner material (TPU/PC or PETG) has minimal impact on this orthodontic procedure.

Authors

Institutions

Publication Details

Journal
Journal of Medical and Biological Engineering
Published
2024-10-01
DOI
https://doi.org/10.1007/s40846-024-00904-5
Citations
4
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
1.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Attachment Design and Aligner Material on Mandibular Canine Distal Bodily Movement in Aligner Treatment

Jui‐Ting Hsu, Pin‐Yu Chen, Heng‐Li Huang, Jian-Hong Yu
4 citations
Journal of Medical and Biological Engineering
Orthodontics and Dentofacial Orthopedics
1.61
article

Effects of Attachment Design and Aligner Material on Mandibular Canine Distal Bodily Movement in Aligner Treatment

Jui‐Ting Hsu, Pin‐Yu Chen, Heng‐Li Huang, Jian-Hong Yu
article en
4 citations

Abstract

Abstract Purpose Dental crowding is a result of a mismatch between tooth size and arch dimensions, which leads to malocclusion; treatment often involves premolar extraction before orthodontic alignment. Clear aligners are limited in their ability to achieve canine distal bodily movement, a common orthodontic maneuver. This study investigated the impacts of attachment design and aligner material on the efficacy of canine distal bodily movement. Methods A finite element analysis was conducted to examine the impact of various attachment designs and two aligner materials, thermoplastic polyurethanes/polycarbonate (TPU/PC) and polyethylene terephthalate glycol-modified (PETG), on mandibular canine distal bodily movement. The investigation focused on the biomechanical responses in the periodontal ligament (PDL) and surrounding alveolar bone. Results Attachment configuration exerted a strong influence on mandibular canine movement. Vertically oriented attachment pairs positioned mesially (mesial occlusal–mesial cervical) resulted in the most effective canine distal bodily movement, followed by a rectangular attachment. TPU/PC aligners induced slightly higher principal stresses in the PDL and von Mises stress and strain in the surrounding alveolar bone compared with PETG aligners; however, the difference was negligible, amounting to less than 6%. Conclusion Attachment design, specifically vertically oriented pairs positioned mesially (mesial occlusal–mesial cervical), was determined to be the crucial factor influencing the efficacy of canine distal bodily movement. The choice of aligner material (TPU/PC or PETG) has minimal impact on this orthodontic procedure.

Journal of Medical and Biological EngineeringVol. 44(5)
Asia University (TW), China Medical University (TW), China Medical University Hospital (TW)
China Medical University, China Medical University, Taiwan
Openalex Percentile: Top 19%
Orthodontics and Dentofacial Orthopedics
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.