8402 The Usefulness Of The Contrast-Enhanced Ultrasound (CEUS) In Preoperative Localization Of Parathyroid Gland Adenomas

Abstract Disclosure: A. Żyłka: None. K. Dobruch-Sobczak: None. H. Piotrzkowska-Wróblewska: None. P. Góralski: None. J. Gałczyński: None. E. Bakuła-Zalewska: None. M. Dedecjus: None. Objectives: Preoperative localization of parathyroid gland adenomas in patients diagnosed with primary hyperparathyroidism (pHPT) is challenging process. The aim of the study was to assessed the usefulness of contrast-enhanced ultrasound (CEUS) as complimentary diagnostic modality to conventional ultrasonography for detection of hyperfunctioning parathyroid gland lesions. Methods: Between the years 2021 and 2022, 36 adult patients (33 women and 3 men, aged 37-76) diagnosed with pHPT, underwent high-resolution ultrasound (US) and CEUS of parathyroid gland adenomas, suspected after fine-needle aspiration biopsy with positive parathormone (PTH) wash-out results and/or avid in 99mTechnetium -sestamibi scintigraphy. During CEUS examination 1.5 ml of SonoVue contrast has been injected and followed by analysing of qualitative CEUS enhancement features. All patients were qualified to surgical treatment according to clinical symptoms, laboratory and imaging findings and underwent parathyroidectomy with histopathologic results confirming parathyroid gland adenomas. Analysis of the B-mode features and visual CEUS enhancement patterns was performed retrospectively. Ten CEUS qualitative parameters of lesions were assessed including: homo- or heterogenous enhancement; hyper- or hypoenhancement; distribution of contrast in wash-in phase as: centripetal, centrifugal or combined and in wash-out phase as: centrally, peripherally or combined. Then the model was extended using the results based on US B-mode imaging which involved size, echogenicity, calcifications, cystic components and vascularity patterns assessed in Color Doppler (CD) and superb microvascular imaging (SMI). Results: Histopathologic results included 36 parathyroid adenomas (in 33 women and 3 men), the medium size 18.8mm (±11.1) and volume 3.7mm3 (±8.2). In B-mode US examination the majority of lesions were assessed as hypoechoic (n=36; 100%) with dominant inhomogenous echostructure (n=20; 55.5%), mixed vascularity (n=24; 66.6%) and polar vessel observed in 14 lesions (38.8%). There were no adenomas with calcifications, cystic components were observed only in 4 nodules (11.1%). In the CEUS study, dominated qualitative features were homogenous (n=22; 61,1%) and hyperenhancement (n=27; 75%), with centripetal distribution of contrast in wash-in phase (n=24; 66,6%) and dominant centrally wash-out of the contrast (n=20; 55,5%). Conclusions: Preliminary results indicate ultrasonographic patterns characteristic for parathyroid gland adenomas in multiparametric ultrasound involved CEUS examination, which seemed to be valuable tool for localization hyperfunctional parathyroid glands. Further multicenter studies should be performed to standardize qualitative CEUS features in order to diagnose primary hyperparathyroidism preoperatively. Presentation: 6/1/2024

Authors

Institutions

Publication Details

Journal
Journal of the Endocrine Society
Published
2024-10-01
DOI
https://doi.org/10.1210/jendso/bvae163.2130
Citations
1
Primary Topic
Parathyroid Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

8402 The Usefulness Of The Contrast-Enhanced Ultrasound (CEUS) In Preoperative Localization Of Parathyroid Gland Adenomas

Katarzyna Dobruch‐Sobczak, Marek Dedecjus, Hanna Piotrzkowska‐Wróblewska, Elwira Bakuła‐Zalewska et al.
1 citations
Journal of the Endocrine Society
Parathyroid Disorders and Treatments
article

8402 The Usefulness Of The Contrast-Enhanced Ultrasound (CEUS) In Preoperative Localization Of Parathyroid Gland Adenomas

Katarzyna Dobruch‐Sobczak, Marek Dedecjus, Hanna Piotrzkowska‐Wróblewska, Elwira Bakuła‐Zalewska, Jacek Gałczyński, Agnieszka Żyłka, Piotr Góralski
article en
1 citations

Abstract

Abstract Disclosure: A. Żyłka: None. K. Dobruch-Sobczak: None. H. Piotrzkowska-Wróblewska: None. P. Góralski: None. J. Gałczyński: None. E. Bakuła-Zalewska: None. M. Dedecjus: None. Objectives: Preoperative localization of parathyroid gland adenomas in patients diagnosed with primary hyperparathyroidism (pHPT) is challenging process. The aim of the study was to assessed the usefulness of contrast-enhanced ultrasound (CEUS) as complimentary diagnostic modality to conventional ultrasonography for detection of hyperfunctioning parathyroid gland lesions. Methods: Between the years 2021 and 2022, 36 adult patients (33 women and 3 men, aged 37-76) diagnosed with pHPT, underwent high-resolution ultrasound (US) and CEUS of parathyroid gland adenomas, suspected after fine-needle aspiration biopsy with positive parathormone (PTH) wash-out results and/or avid in 99mTechnetium -sestamibi scintigraphy. During CEUS examination 1.5 ml of SonoVue contrast has been injected and followed by analysing of qualitative CEUS enhancement features. All patients were qualified to surgical treatment according to clinical symptoms, laboratory and imaging findings and underwent parathyroidectomy with histopathologic results confirming parathyroid gland adenomas. Analysis of the B-mode features and visual CEUS enhancement patterns was performed retrospectively. Ten CEUS qualitative parameters of lesions were assessed including: homo- or heterogenous enhancement; hyper- or hypoenhancement; distribution of contrast in wash-in phase as: centripetal, centrifugal or combined and in wash-out phase as: centrally, peripherally or combined. Then the model was extended using the results based on US B-mode imaging which involved size, echogenicity, calcifications, cystic components and vascularity patterns assessed in Color Doppler (CD) and superb microvascular imaging (SMI). Results: Histopathologic results included 36 parathyroid adenomas (in 33 women and 3 men), the medium size 18.8mm (±11.1) and volume 3.7mm3 (±8.2). In B-mode US examination the majority of lesions were assessed as hypoechoic (n=36; 100%) with dominant inhomogenous echostructure (n=20; 55.5%), mixed vascularity (n=24; 66.6%) and polar vessel observed in 14 lesions (38.8%). There were no adenomas with calcifications, cystic components were observed only in 4 nodules (11.1%). In the CEUS study, dominated qualitative features were homogenous (n=22; 61,1%) and hyperenhancement (n=27; 75%), with centripetal distribution of contrast in wash-in phase (n=24; 66,6%) and dominant centrally wash-out of the contrast (n=20; 55,5%). Conclusions: Preliminary results indicate ultrasonographic patterns characteristic for parathyroid gland adenomas in multiparametric ultrasound involved CEUS examination, which seemed to be valuable tool for localization hyperfunctional parathyroid glands. Further multicenter studies should be performed to standardize qualitative CEUS features in order to diagnose primary hyperparathyroidism preoperatively. Presentation: 6/1/2024

Journal of the Endocrine SocietyVol. 8(Supplement_1)
Institute of Fundamental Technological Research (PL), National Institute of Oncology (HU), Polish Academy of Sciences (PL)
Openalex Percentile: Top 78%
Parathyroid Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.