9173 The Use Of The Frax Tool And Its Adjustments In Women Living With Diabetes: A Cohort Study In Primary Care In Brazil
Abstract Disclosure: F.M. de Oliveira: None. R.M. Leal: None. F.V. Comim: None. M.O. Premaor: None. In recent decades, an increased risk of fractures in people living with diabetes has been described. This risk appears to be independent of bone mineral density (BMD). Therefore, screening instruments for fracture risk have been proposed in this population. The FRAX® algorithm is one of them. However, the initially described FRAX® algorithm has some limitations in PVDM. Some studies suggest that minor modifications to this instrument can improve its performance. These modifications appear to work well in other countries, such as Canada. However, we do not know whether these adjustments work in the Brazilian population. The objective of our study was to evaluate the calibration and accuracy of the FRAX® algorithm with and without adjustments for women living with DM (MLDM). Methods: To this end, a cohort study was carried out that included women receiving primary care in the city of Santa Maria, Rio Grande do Sul. The risk for major and hip fractures was calculated using the FRAX® tool. The FRAX® risk was calculated: 1. Without adjustments (unadjusted FRAX®) 2. Increasing the entered age by ten years in individuals with DM (FRAX® 10 years) 3. Inserting the diagnosis of DM as rheumatoid arthritis (FRAX® AR) Of the 1,301 women eligible to participate in the study, 1,057 were enrolled, and 854 completed the 5-year follow-up. There were no differences between the area under the ROC curve of the unadjusted calculated FRAX® score and the FRAX® 10-year or FRAX® AR for major and hip fractures. The accuracy for major fracture was 0.948 (unadjusted FRAX®), 0.947 (FRAX® 10 years) and 0.946 (FRAX® AR). Furthermore, for hip fractures, the accuracies were 0.989 (unadjusted FRAX®), 0.988 (FRAX® 10 years) and 0.988 (FRAX® AR). On the other hand, both the FRAX® 10 years and the FRAX® AR were better calibrated, presenting a lower Chi-square. The calibration for major and hip fractures was, respectively, 15.4 (FRAX® unadjusted), 14.4 (FRAX® 10 years) and 14.4 (FRAX® AR), and 0.87 (unadjusted FRAX®), 0.32 (FRAX® 10 years) and 0.69 (FRAX® AR). In conclusion, the FRAX algorithm showed good accuracy in WLDM followed in primary care. The FRAX® 10-year and FRAX® AR settings were better calibrated in this population. These data suggest that using the FRAX® tool with adjustments could help identify the risk of fractures in WLDM in primary care in Brazil. Presentation: 6/3/2024
Authors
- Melissa Orlandin Premaor (ORCID: https://orcid.org/0000-0002-0770-9202)
- Fábio Vasconcellos Comim (ORCID: https://orcid.org/0000-0002-2726-233X)
- Rafaela MC Leal
- Fernando Meireles de Oliveira
Institutions
- Universidade Federal de Minas Gerais (BR)
- Universidade Federal de Santa Maria (BR)
Publication Details
- Journal
- Journal of the Endocrine Society
- Published
- 2024-10-01
- DOI
- https://doi.org/10.1210/jendso/bvae163.520
- Primary Topic
- Healthcare Regulation
- Type
- article
- Field-Weighted Citation Impact
- 0.00