Vitreous tissue cryopreservation using a blood vessel model and cryomacroscopy for scale-up studies: Observations and mathematical modeling

Successful long-term cryobanking of multicellular tissues and organs at deep subzero temperatures calls for the avoidance of ice cryoinjury by reliance upon ice-free cryopreservation techniques. However, the quality of the cryopreserved material is the direct result of its ability to survive a host of harmful mechanisms, chief among which is overcoming the trifecta effects of ice crystallization, toxicity, and mechanical stress. This study aims at exploring improved conditions to scale-up ice-free cryopreservation by combining DP6 as a base cryoprotective agent (CPA) solution with an array of synthetic ice modulators (SIMs). This study is conducted by integrating cryomacroscopy techniques, thermal modeling, solid mechanics analysis, and viability and contractility investigation to correlate physical effects, thermal outcomes, and cryobiology results. As an extension of previous work, this study aims at scale-up of established baseline blood vessel models, while comparing the relative toxicity and vitreous stability of 4 ml and 10 ml samples of DP6 containing either sucrose as a SIM, or the commercial synthetic ice blockers (X1000 and Z1000). Using that established protocol, the addition and removal of DP6+0.6M sucrose and DP6 + 1% X1000 + 1% Z1000 were both well tolerated in rabbit carotid and pig femoral artery models, when assessed for metabolic recovery and contractility. Using cryomacroscopy, it was demonstrated that DP6 + 0.6M sucrose provided a stable vitrification medium under marginal cooling and warming conditions that resulted in >50% survival rate. By contrast, DP6 + 1% X1000 + 1% Z1000 was subject to visible ice formation during cooling under the same thermal conditions, resulting in a significantly lower recovery of ∼20%. Thermal modeling is used in this study to verify the actual cooling and rewarming rates in the specimens, while thermomechanics analysis is used to explain why fractures were observed using cryomacroscopy when the specimens were contained in glass vials but not in plastic vials.

Authors

Institutions

Publication Details

Journal
Cryobiology
Published
2024-11-07
DOI
https://doi.org/10.1016/j.cryobiol.2024.104976
Primary Topic
Reproductive Biology and Fertility
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vitreous tissue cryopreservation using a blood vessel model and cryomacroscopy for scale-up studies: Observations and mathematical modeling

Elizabeth D. Greene, Christina Crossley, Kelvin G.M. Brockbank, Yoed Rabin et al.
Cryobiology
Reproductive Biology and Fertility
article

Vitreous tissue cryopreservation using a blood vessel model and cryomacroscopy for scale-up studies: Observations and mathematical modeling

Elizabeth D. Greene, Christina Crossley, Kelvin G.M. Brockbank, Yoed Rabin, Lia H. Campbell, Simona Baicu, Prem K. Solanki, Zhenzhen Chen, Michael J. Taylor
article en

Abstract

Successful long-term cryobanking of multicellular tissues and organs at deep subzero temperatures calls for the avoidance of ice cryoinjury by reliance upon ice-free cryopreservation techniques. However, the quality of the cryopreserved material is the direct result of its ability to survive a host of harmful mechanisms, chief among which is overcoming the trifecta effects of ice crystallization, toxicity, and mechanical stress. This study aims at exploring improved conditions to scale-up ice-free cryopreservation by combining DP6 as a base cryoprotective agent (CPA) solution with an array of synthetic ice modulators (SIMs). This study is conducted by integrating cryomacroscopy techniques, thermal modeling, solid mechanics analysis, and viability and contractility investigation to correlate physical effects, thermal outcomes, and cryobiology results. As an extension of previous work, this study aims at scale-up of established baseline blood vessel models, while comparing the relative toxicity and vitreous stability of 4 ml and 10 ml samples of DP6 containing either sucrose as a SIM, or the commercial synthetic ice blockers (X1000 and Z1000). Using that established protocol, the addition and removal of DP6+0.6M sucrose and DP6 + 1% X1000 + 1% Z1000 were both well tolerated in rabbit carotid and pig femoral artery models, when assessed for metabolic recovery and contractility. Using cryomacroscopy, it was demonstrated that DP6 + 0.6M sucrose provided a stable vitrification medium under marginal cooling and warming conditions that resulted in >50% survival rate. By contrast, DP6 + 1% X1000 + 1% Z1000 was subject to visible ice formation during cooling under the same thermal conditions, resulting in a significantly lower recovery of ∼20%. Thermal modeling is used in this study to verify the actual cooling and rewarming rates in the specimens, while thermomechanics analysis is used to explain why fractures were observed using cryomacroscopy when the specimens were contained in glass vials but not in plastic vials.

CryobiologyVol. 117
Applied Tissue Technologies (United States) (US), Cell and Tissue Systems (United States) (US), Jan Biotech (United States) (US), Carnegie Mellon University (US), Clemson University (US)
National Institutes of Health, National Heart, Lung, and Blood Institute
Clean water and sanitation
Openalex Percentile: Top 74%
Reproductive Biology and Fertility
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.