Energy performance and wind exposure of windward, lateral, and leeward high-rise photovoltaic facades

The growing demand for sustainable energy solutions leads to the integration of photovoltaic/thermal (PV/T) modules into building facades. This study evaluates and compares the energy potential, wind load, and environmental benefits of PV/T modules installed on different facades of high-rise buildings. Using advanced computational techniques, including Computational Fluid Dynamics (CFD), the wind interaction with PV/T modules on windward, lateral, and leeward facades is modeled and analyzed. Each computational process requires over two weeks to complete due to the complexity of the simulations. The results demonstrate that the leeward facade is more effective for electricity generation, while the windward and sideward facades perform better for thermal energy storage. Maximum energy outputs of 217 kW for thermal energy and 73 kW for electrical energy are recorded, depending on wind conditions. Additionally, energetic and exergetic efficiencies reach 55.2 % and 17.7 %, respectively. The study also finds that the leeward facade has the greatest impact on reducing CO 2 emissions. These findings provide valuable insights into designing optimal PV/T facades for high-rise structures, expanding the range of structural designs and offering opportunities for implementing mitigation measures to enhance system durability and efficiency. The novelty of this research lies in the detailed comparative analysis of PV/T performance across multiple facades, offering a practical framework for future sustainable building designs. • Energy capacity of photovoltaics is studied on windward, side, and leeward facades. • Windward façade achieves the highest total efficiency of 55.2 %. • Leeward façade produces the highest power with electrical efficiency of 15.3 %. • Windward façade shows superior performance in heating production. • Photovoltaic system undergoes the lowest wind load on the leeward façade.

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2024-10-04
DOI
https://doi.org/10.1016/j.jobe.2024.110956
Citations
8
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
2.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy performance and wind exposure of windward, lateral, and leeward high-rise photovoltaic facades

Towhid Gholizadeh, Javad Bezaatpour, Hadi Ghaebi, Mojtaba Bezaatpour
8 citations
Journal of Building Engineering
Building Energy and Comfort Optimization
2.12
article

Energy performance and wind exposure of windward, lateral, and leeward high-rise photovoltaic facades

Towhid Gholizadeh, Javad Bezaatpour, Hadi Ghaebi, Mojtaba Bezaatpour
article en
8 citations

Abstract

The growing demand for sustainable energy solutions leads to the integration of photovoltaic/thermal (PV/T) modules into building facades. This study evaluates and compares the energy potential, wind load, and environmental benefits of PV/T modules installed on different facades of high-rise buildings. Using advanced computational techniques, including Computational Fluid Dynamics (CFD), the wind interaction with PV/T modules on windward, lateral, and leeward facades is modeled and analyzed. Each computational process requires over two weeks to complete due to the complexity of the simulations. The results demonstrate that the leeward facade is more effective for electricity generation, while the windward and sideward facades perform better for thermal energy storage. Maximum energy outputs of 217 kW for thermal energy and 73 kW for electrical energy are recorded, depending on wind conditions. Additionally, energetic and exergetic efficiencies reach 55.2 % and 17.7 %, respectively. The study also finds that the leeward facade has the greatest impact on reducing CO 2 emissions. These findings provide valuable insights into designing optimal PV/T facades for high-rise structures, expanding the range of structural designs and offering opportunities for implementing mitigation measures to enhance system durability and efficiency. The novelty of this research lies in the detailed comparative analysis of PV/T performance across multiple facades, offering a practical framework for future sustainable building designs. • Energy capacity of photovoltaics is studied on windward, side, and leeward facades. • Windward façade achieves the highest total efficiency of 55.2 %. • Leeward façade produces the highest power with electrical efficiency of 15.3 %. • Windward façade shows superior performance in heating production. • Photovoltaic system undergoes the lowest wind load on the leeward façade.

Journal of Building EngineeringVol. 97
Sahand University of Technology (IR), Silesian University of Technology (PL), Tampere University (FI), University of Mohaghegh Ardabili (IR)
Affordable and clean energy
Openalex Percentile: Top 14%
Building Energy and Comfort Optimization
2.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.