Evaluation of marginal fit of conventional, milled, and direct metal laser sintered cobalt chromium crowns: A comparative study

Introduction: A close marginal adaptation of a fixed partial denture is crucial for its long-term functionality without any adversity. Human errors and casting defects are common with conventional techniques. The latest techniques, direct metal laser sintering (DMLS), and computer-aided design and manufacturing (CAD/CAM) tend to overcome these errors. Methods: 33 dies were fabricated from similar number of impressions of a tooth based on standardized measurement and were equally distributed in 3 groups (11 each). Crowns were fabricated using conventional, DMLS, and CAD/CAM methods using chrome-cobalt. All the fabricated crowns were cemented onto the die using resin cement and 50 N force, followed by leaving them for 12 hours at room temperature. Then, each crown was sectioned into two halves, and a stereomicroscope was used to evaluate the cement thickness at three different reference points. Results: The marginal fit of conventionally fabricated crowns, DMLS, and CAD/CAM crowns were in the clinically acceptable range. Marginal discrepancy remained more in conventionally fabricated crowns than in CAD/CAM and DMLS crowns. However, the axial discrepancy in crowns fabricated by the conventional method was lesser than in CAD/CAM and DMLS fabricated crowns. The occlusal discrepancy in DMLS-fabricated crowns was more than that of the other two methods. Conclusion: The DMLS group displayed better marginal accuracy with respect to the marginal reference point. On the other hand, the convention group exhibited superior adaptability when the buccal and occlusal reference points were considered. Similarly, statistically significant results were observed when the conventional group's 'margin reference point' was compared with the CAD/CAM or DMLS group. The margin reference point of the CAD/CAM group was comparable with DMLS cobalt-chromium crowns.

Authors

Institutions

Publication Details

Journal
Journal of Nepalese Prosthodontic Society
Published
2024-10-04
DOI
https://doi.org/10.3126/jnprossoc.v7i1.70455
Primary Topic
Additive Manufacturing Materials and Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of marginal fit of conventional, milled, and direct metal laser sintered cobalt chromium crowns: A comparative study

Jitendra Sharan, Pawan Sinha, Smriti KC Basnyat, S Munireddy et al.
Journal of Nepalese Prosthodontic Society
Additive Manufacturing Materials and Processes
article

Evaluation of marginal fit of conventional, milled, and direct metal laser sintered cobalt chromium crowns: A comparative study

Jitendra Sharan, Pawan Sinha, Smriti KC Basnyat, S Munireddy, GK Chauhan, Sandeep Srinivas
article en

Abstract

Introduction: A close marginal adaptation of a fixed partial denture is crucial for its long-term functionality without any adversity. Human errors and casting defects are common with conventional techniques. The latest techniques, direct metal laser sintering (DMLS), and computer-aided design and manufacturing (CAD/CAM) tend to overcome these errors. Methods: 33 dies were fabricated from similar number of impressions of a tooth based on standardized measurement and were equally distributed in 3 groups (11 each). Crowns were fabricated using conventional, DMLS, and CAD/CAM methods using chrome-cobalt. All the fabricated crowns were cemented onto the die using resin cement and 50 N force, followed by leaving them for 12 hours at room temperature. Then, each crown was sectioned into two halves, and a stereomicroscope was used to evaluate the cement thickness at three different reference points. Results: The marginal fit of conventionally fabricated crowns, DMLS, and CAD/CAM crowns were in the clinically acceptable range. Marginal discrepancy remained more in conventionally fabricated crowns than in CAD/CAM and DMLS crowns. However, the axial discrepancy in crowns fabricated by the conventional method was lesser than in CAD/CAM and DMLS fabricated crowns. The occlusal discrepancy in DMLS-fabricated crowns was more than that of the other two methods. Conclusion: The DMLS group displayed better marginal accuracy with respect to the marginal reference point. On the other hand, the convention group exhibited superior adaptability when the buccal and occlusal reference points were considered. Similarly, statistically significant results were observed when the conventional group's 'margin reference point' was compared with the CAD/CAM or DMLS group. The margin reference point of the CAD/CAM group was comparable with DMLS cobalt-chromium crowns.

Journal of Nepalese Prosthodontic SocietyVol. 7(1)
Bihar Agricultural University (IN), Oxford Dental College and Hospital (IN), All India Institute of Medical Sciences Bhubaneswar (IN), Maaruti College of Dental sciences & Research Center (IN), Hi-Tech Medical College & Hospital (IN), Kathmandu University (NP)
Openalex Percentile: Top 83%
Additive Manufacturing Materials and Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.