Simulation of a Heating System Cascade Proportional-Integral Controller

The article considers a model of a cascade PI (proportional-integral) controller of a building heating control system. The relevance of the research based on the results of the analysis of sources on the example of Russia is shown. The controller circuit is described, which allows for smooth control of the room temperature by controlling the supply of the heating system. A model of the controller and control system in the Logo!Soft Comfort, which takes into account the direct connection between the outdoor temperature and the temperature feedback in heated rooms. Based on the results of experiments using a simulation model, graphs for regulating the temperature of the heating system heat carrier when the external temperature changes from minus 6 °C to minus 36°C in increments of 10 degrees were obtained. Tests of the model were carried out when the indoor air temperature settings were increased and decreased. The results demonstrating the adaptability and effectiveness of the proposed regulator of the heating control system with changes in external factors and settings are obtained. The conclusion is made about the possibility of using this regulator in heating systems.

Authors

Institutions

Publication Details

Published
2024-09-08
DOI
https://doi.org/10.1109/rusautocon61949.2024.10693987
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation of a Heating System Cascade Proportional-Integral Controller

George Palkin, Roman Dolgih, Роман Горбунов
Induction Heating and Inverter Technology
article

Simulation of a Heating System Cascade Proportional-Integral Controller

George Palkin, Roman Dolgih, Роман Горбунов
article en

Abstract

The article considers a model of a cascade PI (proportional-integral) controller of a building heating control system. The relevance of the research based on the results of the analysis of sources on the example of Russia is shown. The controller circuit is described, which allows for smooth control of the room temperature by controlling the supply of the heating system. A model of the controller and control system in the Logo!Soft Comfort, which takes into account the direct connection between the outdoor temperature and the temperature feedback in heated rooms. Based on the results of experiments using a simulation model, graphs for regulating the temperature of the heating system heat carrier when the external temperature changes from minus 6 °C to minus 36°C in increments of 10 degrees were obtained. Tests of the model were carried out when the indoor air temperature settings were increased and decreased. The results demonstrating the adaptability and effectiveness of the proposed regulator of the heating control system with changes in external factors and settings are obtained. The conclusion is made about the possibility of using this regulator in heating systems.

Transbaikal State University (RU)
Affordable and clean energy
Openalex Percentile: Top 83%
Induction Heating and Inverter Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation of a Heating System Cascade Proportional-Integral Controller — George Palkin, Roman Dolgih, et al. · (2024) | TGRS Research Map | TGRS