Simulation of TEC1-12706 for Use in In Vitro Studies of the Gastrointestinal Tract of Animals

In vitro modeling the gastrointestinal tract of animals is a complex task. Therefore, this article considers a part of the entire environmental parameter control system responsible for the temperature of the chyme in the bioreactor. The use of the thermoelectric converter TEC1-12706 is necessary because of the small working volumes of the bioreactor (from 50 to 200 ml) and because of the possibility of its operation for both heating and cooling, which is critically important for modeling a wide range of gastrointestinal tract of animals. For example, to simulate the digestive tract of a sterlet, the chyme temperature should be about 14°C, and for a chicken 42 °C. Thus, the mathematical model considered in this paper will allow us to create a thermodynamic model of the entire system with a bioreactor and evaluate the applicability of the TEC1-12706 converter for mini in vitro static systems. And in the future, this will allow us to develop a general model of a bioreactor to assess its thermodynamic characteristics, taking into account the dynamics of mixing, to describe mathematically chemical processes and the influence of temperature on them.

Authors

Institutions

Publication Details

Published
2024-09-08
DOI
https://doi.org/10.1109/rusautocon61949.2024.10694184
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation of TEC1-12706 for Use in In Vitro Studies of the Gastrointestinal Tract of Animals

Alexander Lukyanov, Danila Donskoy
1 links
Radiomics and Machine Learning in Medical Imaging
article

Simulation of TEC1-12706 for Use in In Vitro Studies of the Gastrointestinal Tract of Animals

Alexander Lukyanov, Danila Donskoy
article en

Abstract

In vitro modeling the gastrointestinal tract of animals is a complex task. Therefore, this article considers a part of the entire environmental parameter control system responsible for the temperature of the chyme in the bioreactor. The use of the thermoelectric converter TEC1-12706 is necessary because of the small working volumes of the bioreactor (from 50 to 200 ml) and because of the possibility of its operation for both heating and cooling, which is critically important for modeling a wide range of gastrointestinal tract of animals. For example, to simulate the digestive tract of a sterlet, the chyme temperature should be about 14°C, and for a chicken 42 °C. Thus, the mathematical model considered in this paper will allow us to create a thermodynamic model of the entire system with a bioreactor and evaluate the applicability of the TEC1-12706 converter for mini in vitro static systems. And in the future, this will allow us to develop a general model of a bioreactor to assess its thermodynamic characteristics, taking into account the dynamics of mixing, to describe mathematically chemical processes and the influence of temperature on them.

Don State Technical University (RU)
Russian Science Foundation
Zero hunger
Openalex Percentile: Top 71%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation of TEC1-12706 for Use in In Vitro Studies of the Gastrointestinal Tract of Animals — Alexander Lukyanov, Danila Donskoy · (2024) | TGRS Research Map | TGRS