Influence of Conductor Arrangement and Termination Loads on Modal Redundancy Efficiency in a Four-Conductor Modal Filter

This paper presents the results of analyzing a four-conductor modal filter under trapezoidal noise influence on the time response at the device output. Thus, the use of matched terminations loads at the ends of far conductors allows to obtain 2.5% lower amplitudes at the output of the device relative to closely located ones. For the case of closely spaced conductors, the smallest amplitudes at the device output are observed with a combination of short circuit terminations loads at the far end and open circuit at the near end. Such allows to obtain up to 36.5% lower amplitudes relative to the far ones. Using the outer conductors as active conductors further reduces the amplitudes at the output of the device by up to 16.8 per cent percent. The terminations loads of conductors located through the air gap have no effect on the signal amplitude at the output of the protective device.

Authors

Institutions

Publication Details

Published
2024-09-08
DOI
https://doi.org/10.1109/rusautocon61949.2024.10694248
Primary Topic
Advanced Algorithms and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Conductor Arrangement and Termination Loads on Modal Redundancy Efficiency in a Four-Conductor Modal Filter

Alexandr M. Lakoza, Evgeniya B. Chernikova, Valerii P. Kosteletskii
Advanced Algorithms and Applications
article

Influence of Conductor Arrangement and Termination Loads on Modal Redundancy Efficiency in a Four-Conductor Modal Filter

Alexandr M. Lakoza, Evgeniya B. Chernikova, Valerii P. Kosteletskii
article en

Abstract

This paper presents the results of analyzing a four-conductor modal filter under trapezoidal noise influence on the time response at the device output. Thus, the use of matched terminations loads at the ends of far conductors allows to obtain 2.5% lower amplitudes at the output of the device relative to closely located ones. For the case of closely spaced conductors, the smallest amplitudes at the device output are observed with a combination of short circuit terminations loads at the far end and open circuit at the near end. Such allows to obtain up to 36.5% lower amplitudes relative to the far ones. Using the outer conductors as active conductors further reduces the amplitudes at the output of the device by up to 16.8 per cent percent. The terminations loads of conductors located through the air gap have no effect on the signal amplitude at the output of the protective device.

Tomsk State University of Control Systems and Radio-Electronics (RU)
Russian Science Foundation
Openalex Percentile: Top 81%
Advanced Algorithms and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of Conductor Arrangement and Termination Loads on Modal Redundancy Efficiency in a Four-Conductor Modal Filter — Alexandr M. Lakoza, Evgeniya B. Chernikova, et al. · (2024) | TGRS Research Map | TGRS