A Radar Contactless Blood Pressure Detection Technology based on Pulse Waves Using High-order Polynomial Regression

Compared with cuff-contact Blood Pressure (BP) measurement methods such as mercury sphygmomanometers, radar contactless BP detection technology has good application prospects in fields for patients with burns, infectious diseases, or homecare health monitoring due to its ability to continuously monitor BP for a long time without any constraints. Currently, research in this area is mainly based on the pulse transit time (PTT). In this paper, a PTT BP fitting method based on a high-order polynomial regression model was proposed, which uses a 24-GHz continuous wave radar to collect 42 sets of radial artery data from two subjects for seven days. Three regression models were applied for BP calculation and the results were shown. Compared with linear regression and logarithmic regression, the proposed method performed better in terms of the R-square, Root Mean Square Error(RMSE), and Mean Absolute Error(MAE). The Mean Deviation(MD) and Standard Deviation(SD) of systolic and diastolic BP were -0.106 ± 0.474 mmHg and 0.574 ± 2.161 mmHg, respectively. The feasibility and accuracy of this method was demonstrated.

Authors

Institutions

Publication Details

Published
2024-08-16
DOI
https://doi.org/10.1109/aces-china62474.2024.10699541
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Radar Contactless Blood Pressure Detection Technology based on Pulse Waves Using High-order Polynomial Regression

Xinyu Wang, Ye Liu, Yang Zhang, Xiongce Lv
Non-Invasive Vital Sign Monitoring
article

A Radar Contactless Blood Pressure Detection Technology based on Pulse Waves Using High-order Polynomial Regression

Xinyu Wang, Ye Liu, Yang Zhang, Xiongce Lv
article en

Abstract

Compared with cuff-contact Blood Pressure (BP) measurement methods such as mercury sphygmomanometers, radar contactless BP detection technology has good application prospects in fields for patients with burns, infectious diseases, or homecare health monitoring due to its ability to continuously monitor BP for a long time without any constraints. Currently, research in this area is mainly based on the pulse transit time (PTT). In this paper, a PTT BP fitting method based on a high-order polynomial regression model was proposed, which uses a 24-GHz continuous wave radar to collect 42 sets of radial artery data from two subjects for seven days. Three regression models were applied for BP calculation and the results were shown. Compared with linear regression and logarithmic regression, the proposed method performed better in terms of the R-square, Root Mean Square Error(RMSE), and Mean Absolute Error(MAE). The Mean Deviation(MD) and Standard Deviation(SD) of systolic and diastolic BP were -0.106 ± 0.474 mmHg and 0.574 ± 2.161 mmHg, respectively. The feasibility and accuracy of this method was demonstrated.

Xi'an Technological University (CN), Air Force Medical University (CN)
Openalex Percentile: Top 84%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Radar Contactless Blood Pressure Detection Technology based on Pulse Waves Using High-order Polynomial Regression — Xinyu Wang, Ye Liu, et al. · (2024) | TGRS Research Map | TGRS