Assessment of OH femtosecond thermally assisted fluorescence thermometry for hydrogen non-premixed flames
In this work, we further developed the planar temperature measurement method based on thermally assisted laser-induced fluorescence (TALF) with a single femtosecond (fs) laser and investigated the temperature distribution in the nitrogen-diluted oxygen–hydrogen cross-jet non-premixed flames at 1 kHz. Fs-TALF thermometry was firstly calibrated and assessed in a series of unconfined methane/air laminar flames at atmospheric pressure. In the calibration process, although the calibrated energy difference between OH v ′ = 0 and 1 energy level was different from the theoretical value, the measured fluorescence ratio accurately reflected the temperature change from 1600 K to 2200 K in different methane flames. By comparing the calculated OH fluorescence spectrum, we believed that the main reason was the overlap of the OH (1-1) and (0-0) fluorescence bands. After the calibration, experiments were conducted with changing hydrogen flow velocity from 60 to 100 m/s and constant oxidizer flow velocity, where the dilution ratio, D varies from 0.46 to 0.7, and the equivalence ratio, ϕ , varies from 0.5 to 0.9. It is found, within the calibration range, fs-TALF thermometry can correctly measure the flame temperature. However, with ϕ further increases, the difference between the measured and theoretical temperatures gradually increases. At the same time, it was noted that the error in the measured temperature rises gradually as D decreases. In conclusion, fs-TALF thermometry can measure turbulent non-premixed hydrogen flames accurately in a range of temperature with acceptable temporal and partial resolution, while the errors within 200 K and spatial resolution is 170 μ m . The main error source should be the collisional effect due to the different local concentration of N 2 and H 2 O. The results of this work will contribute to the further development the temperature measurement method hydrogen turbulent flames. • Fs OH TALF was assessed in laminar flame. • Temperature distribution of turbulent flames was first measured by Fs OH TALF. • N 2 , O 2 and H 2 O collision is the main error source. • The temporal temperature distribution of hydrogen micromix flames were first studied. • The incomplete combustion might happen for the multi-impinging hydrogen burner.
Authors
- Mamoru Tanahashi (ORCID: https://orcid.org/0000-0003-2828-0609)
- Sibo Huang (ORCID: https://orcid.org/0000-0003-2402-4042)
- Masayasu Shimura (ORCID: https://orcid.org/0000-0002-3172-3215)
- Kentaro Hayashi (ORCID: https://orcid.org/0000-0002-2936-9544)
- Yuki Tochinai
Institutions
- Tokyo Institute of Technology (JP)
- National Institute of Advanced Industrial Science and Technology (JP)
Publication Details
- Journal
- Applied Thermal Engineering
- Published
- 2024-10-05
- DOI
- https://doi.org/10.1016/j.applthermaleng.2024.124517
- Citations
- 2
- Primary Topic
- Combustion and flame dynamics
- Type
- article
- Field-Weighted Citation Impact
- 0.75
Funders
- New Energy and Industrial Technology Development Organization
- New Energy and Industrial Technology Development Organization
- Japan Science and Technology Agency