Implementation of a simple functionalisation of graphene (Gii-Sens) in the determination of a suitable linker for use in biocatalytic devices

• Novel graphene foams are shown to be ideal electrodes for glucose biosensors. • XPS and Raman characterise electrodes and their modification with pyrene-NHS. • GDH successfully immobilised on pyrene-NHS functionalised graphene foam. • Linear response to increasing glucose concentration over suitable range. • Glucose sensitivity of 22.7 μA/mM/cm ^2 shows promise of this metal-free sensor. We adapted a single-step method to functionalise three-dimensional graphene foam (Gii-Sens) electrodes with a 1-pyrenebutyric acid N-hydroxysuccinimide ester (Pyr-NHS). The physical and chemical properties of these functionalised electrodes were subsequently probed via Raman spectroscopy, X-ray photoelectron spectroscopy, and field-emission scanning electron microscopy. Combined with data acquired from cyclic voltammetry and electrical impedance spectroscopy, we confirmed the presence of Pyr-NHS on the surface of the graphene foam in sufficient quantity for it to serve as a suitable linker for the immobilisation of the enzyme glucose dehydrogenase (GDH) on the electrode. Evidence of this immobilisation was provided through electrochemical characterisation, before demonstrating an active enzyme response from GDH via the mediated oxidation of glucose at the electrode surface. A proportional relationship between the concentration of glucose and the peak anodic current from the redox mediator p-aminophenol led to the determination of a high sensitivity of 22.7 µA/mM/cm 2 and a limit of detection of 5.25 µM. Such a result confirms the viability of these functionalised graphene foam electrodes as a metal-free high-performing anode within miniaturised, glucose-based biocatalytic devices, including enzymatic biofuel cells and biosensors.

Authors

Institutions

Publication Details

Journal
Applied Surface Science
Published
2024-10-05
DOI
https://doi.org/10.1016/j.apsusc.2024.161426
Citations
7
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of a simple functionalisation of graphene (Gii-Sens) in the determination of a suitable linker for use in biocatalytic devices

Michael‐John Treanor, Yousillya Bunga, Pablo Lozano-Sánchez, Renald Schaub et al.
7 citations
Applied Surface Science
Electrochemical sensors and biosensors
1.46
article

Implementation of a simple functionalisation of graphene (Gii-Sens) in the determination of a suitable linker for use in biocatalytic devices

Michael‐John Treanor, Yousillya Bunga, Pablo Lozano-Sánchez, Renald Schaub, Marco Caffio
article en
7 citations

Abstract

• Novel graphene foams are shown to be ideal electrodes for glucose biosensors. • XPS and Raman characterise electrodes and their modification with pyrene-NHS. • GDH successfully immobilised on pyrene-NHS functionalised graphene foam. • Linear response to increasing glucose concentration over suitable range. • Glucose sensitivity of 22.7 μA/mM/cm ^2 shows promise of this metal-free sensor. We adapted a single-step method to functionalise three-dimensional graphene foam (Gii-Sens) electrodes with a 1-pyrenebutyric acid N-hydroxysuccinimide ester (Pyr-NHS). The physical and chemical properties of these functionalised electrodes were subsequently probed via Raman spectroscopy, X-ray photoelectron spectroscopy, and field-emission scanning electron microscopy. Combined with data acquired from cyclic voltammetry and electrical impedance spectroscopy, we confirmed the presence of Pyr-NHS on the surface of the graphene foam in sufficient quantity for it to serve as a suitable linker for the immobilisation of the enzyme glucose dehydrogenase (GDH) on the electrode. Evidence of this immobilisation was provided through electrochemical characterisation, before demonstrating an active enzyme response from GDH via the mediated oxidation of glucose at the electrode surface. A proportional relationship between the concentration of glucose and the peak anodic current from the redox mediator p-aminophenol led to the determination of a high sensitivity of 22.7 µA/mM/cm 2 and a limit of detection of 5.25 µM. Such a result confirms the viability of these functionalised graphene foam electrodes as a metal-free high-performing anode within miniaturised, glucose-based biocatalytic devices, including enzymatic biofuel cells and biosensors.

Applied Surface ScienceVol. 680
University of St Andrews (GB), Applied Graphene Materials (United Kingdom) (GB)
UK Research and Innovation, Scottish Funding Council, University of St Andrews, Engineering and Physical Sciences Research Council, Innovate UK
Openalex Percentile: Top 17%
Electrochemical sensors and biosensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.