Selection and evaluation of commercial low-cost devices for indoor air quality monitoring in schools

The use of low-cost sensors for monitoring Indoor Air Quality (IAQ) in schools has shown promising results, with the commercialisation of these devices increasing worldwide. This study aims to identify an effective, commercially available low-cost device for IAQ monitoring in schools. Four low-cost devices (AirVisual Pro, PocketLab Air, PurpleAir PA-II-SD and uRAD Monitor A3) were selected for both qualitative and performance evaluations. Field tests were conducted in six indoor microenvironments within a nursery and a primary school. The low-cost devices were co-located with research-grade instruments to obtain reference concentrations of PM 1 , PM 2.5 , PM 10 , CO 2 , VOC, formaldehyde and O 3 . The qualitative evaluation revealed limitations, including data loss, negative or erratic values, inconsistent timestamps, and connectivity issues. PM low-cost devices exhibited better performance during non-occupancy periods but faced challenges during periods of occupancy. All devices tended to underestimate measurements compared to reference data, although AirVisual Pro performed better for PM 2.5 during occupancy. Furthermore, CO 2 concentrations were slightly overestimated, showing improved accuracy during occupancy periods. While formaldehyde peaks were detected by the low-cost device, overall performance was weak for both formaldehyde and O 3 . The results indicated that AirVisual Pro demonstrated the best overall performance, and presents itself as a promising tool for IAQ monitoring in schools. However, performance evaluations should be tailored to specific microenvironments and occupancy periods. Despite some acceptable performance results, real-context use of the selected low-cost device should be preceded by a proper calibration. Additionally, long-term performance evaluation should be considered in future studies. • Four devices were selected for an effective low-cost IAQ monitoring. • The selected devices underwent in-field performance evaluation in schools. • Performance evaluation should be done in different microenvironments and occupancy. • Using low-cost devices in-field should be preceded by a proper calibration.

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2024-10-05
DOI
https://doi.org/10.1016/j.jobe.2024.110952
Citations
8
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
1.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Selection and evaluation of commercial low-cost devices for indoor air quality monitoring in schools

Sofia Sousa, M.C.M. Alvim-Ferraz, F.G. Martins, Juliana P. Sá et al.
8 citations
Journal of Building Engineering
Air Quality Monitoring and Forecasting
1.65
article

Selection and evaluation of commercial low-cost devices for indoor air quality monitoring in schools

Sofia Sousa, M.C.M. Alvim-Ferraz, F.G. Martins, Juliana P. Sá, P.T.B.S. Branco, H. Chojer, A. Forstmaier
article en
8 citations

Abstract

The use of low-cost sensors for monitoring Indoor Air Quality (IAQ) in schools has shown promising results, with the commercialisation of these devices increasing worldwide. This study aims to identify an effective, commercially available low-cost device for IAQ monitoring in schools. Four low-cost devices (AirVisual Pro, PocketLab Air, PurpleAir PA-II-SD and uRAD Monitor A3) were selected for both qualitative and performance evaluations. Field tests were conducted in six indoor microenvironments within a nursery and a primary school. The low-cost devices were co-located with research-grade instruments to obtain reference concentrations of PM 1 , PM 2.5 , PM 10 , CO 2 , VOC, formaldehyde and O 3 . The qualitative evaluation revealed limitations, including data loss, negative or erratic values, inconsistent timestamps, and connectivity issues. PM low-cost devices exhibited better performance during non-occupancy periods but faced challenges during periods of occupancy. All devices tended to underestimate measurements compared to reference data, although AirVisual Pro performed better for PM 2.5 during occupancy. Furthermore, CO 2 concentrations were slightly overestimated, showing improved accuracy during occupancy periods. While formaldehyde peaks were detected by the low-cost device, overall performance was weak for both formaldehyde and O 3 . The results indicated that AirVisual Pro demonstrated the best overall performance, and presents itself as a promising tool for IAQ monitoring in schools. However, performance evaluations should be tailored to specific microenvironments and occupancy periods. Despite some acceptable performance results, real-context use of the selected low-cost device should be preceded by a proper calibration. Additionally, long-term performance evaluation should be considered in future studies. • Four devices were selected for an effective low-cost IAQ monitoring. • The selected devices underwent in-field performance evaluation in schools. • Performance evaluation should be done in different microenvironments and occupancy. • Using low-cost devices in-field should be preceded by a proper calibration.

Journal of Building EngineeringVol. 98
Universidade do Porto (PT), Technical University of Munich (DE)
Openalex Percentile: Top 18%
Air Quality Monitoring and Forecasting
1.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.