Voltammetric Characterization and Quantification of the Cocaine Analog Nitracaine

Abstract Synthetic cocaine analogs are designer drugs that recently emerged as non‐controlled substitutes for their parent drug. Among them, nitracaine is of particular concern for its psychoactive effect. In this work, we present a thorough characterization of the electrochemical behavior of nitracaine, with a final quantification performed by differential pulse voltammetry (DPV) in ethanol/lithium perchlorate 0.1 M. The selectivity of the method and reproducibility of results were assessed. LOQ of 0.3 μg mL −1 and a linear dynamic range of up to 400 μg mL −1 were obtained. In addition, recoveries from 85 % to 101 % were achieved on both simulated and real samples. For nitracaine analysis in urine, a clean‐up and a preconcentration step by solid phase extraction (SPE) using the adsorbent Florisil have been developed and optimized through the Design of Experiments (DoE) strategy, thus achieving an enrichment factor of 20.

Authors

Institutions

Publication Details

Journal
ChemElectroChem
Published
2024-10-02
DOI
https://doi.org/10.1002/celc.202400386
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Voltammetric Characterization and Quantification of the Cocaine Analog Nitracaine

Giancarla Alberti, Daniele Merli, Alessandra Bonanni, Federica Baldi et al.
ChemElectroChem
Analytical Chemistry and Chromatography
article

Voltammetric Characterization and Quantification of the Cocaine Analog Nitracaine

Giancarla Alberti, Daniele Merli, Alessandra Bonanni, Federica Baldi, Protti Stefano
article en

Abstract

Abstract Synthetic cocaine analogs are designer drugs that recently emerged as non‐controlled substitutes for their parent drug. Among them, nitracaine is of particular concern for its psychoactive effect. In this work, we present a thorough characterization of the electrochemical behavior of nitracaine, with a final quantification performed by differential pulse voltammetry (DPV) in ethanol/lithium perchlorate 0.1 M. The selectivity of the method and reproducibility of results were assessed. LOQ of 0.3 μg mL −1 and a linear dynamic range of up to 400 μg mL −1 were obtained. In addition, recoveries from 85 % to 101 % were achieved on both simulated and real samples. For nitracaine analysis in urine, a clean‐up and a preconcentration step by solid phase extraction (SPE) using the adsorbent Florisil have been developed and optimized through the Design of Experiments (DoE) strategy, thus achieving an enrichment factor of 20.

ChemElectroChemVol. 11(20)
University of Pavia (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Milano Bicocca (IT)
Dipartimenti di Eccellenza, Università degli Studi di Pavia, Ministero dell'Università e della Ricerca
Openalex Percentile: Top 87%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.