Optimization of ventilation efficiency in tunnel-type underground spaces using response surface methodology: a case study of Yunlong Mountain civil defense in Xuzhou

Civil defense projects, designed as wartime underground spaces, often lack effective natural ventilation and have considerable depth, which complicates their use as public spaces in peacetime. However, the application of passive ventilation technologies can create effective airflow channels within these structures, significantly enhancing ventilation efficiency and thus improving the overall thermal comfort level. For this study, air age, along with average wind speed, temperature, and relative humidity as stipulated by the "Requirements for Environmental Sanitation of Civil Air Defense Works during Peacetime Use" (GBT 17216-2012), were selected as evaluation metrics. This paper compares the ventilation effectiveness between single ventilation shafts and multiple ventilation shafts under positive and negative pressure conditions in underground civil defense structures. The results indicate that negative pressure ventilation in multiple shaft configurations performs optimally across various ventilation approaches. Subsequently, the Response Surface Methodology (RSM) was utilized to further optimize the positioning of multiple ventilation shafts. The study examined the impact of three ventilation shaft locations on average wind speed, temperature, relative humidity, and air age, leading to an optimized design. Specifically, the optimal positions are 54.76 m for Shaft A, 51.45 m for Shaft B, and 79.85 m for Shaft C, achieving an average wind speed of 0.222 m/s, a temperature of 26 °C, a relative humidity reduction to 85.47%, and an average air age of 10.57 s. This research provides practical insights for the optimization of ventilation in underground civil defense facilities.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-03
DOI
https://doi.org/10.1038/s41598-024-73059-7
Citations
2
Primary Topic
Underground infrastructure and sustainability
Type
article
Field-Weighted Citation Impact
0.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of ventilation efficiency in tunnel-type underground spaces using response surface methodology: a case study of Yunlong Mountain civil defense in Xuzhou

Xiaochun Hong, Feiyu Huang, Haifeng Zhang, Jijun Lu et al.
2 citations
Scientific Reports
Underground infrastructure and sustainability
0.53
article

Optimization of ventilation efficiency in tunnel-type underground spaces using response surface methodology: a case study of Yunlong Mountain civil defense in Xuzhou

Xiaochun Hong, Feiyu Huang, Haifeng Zhang, Jijun Lu, Yuan Ji, Jinggang Dong
article en
2 citations

Abstract

Civil defense projects, designed as wartime underground spaces, often lack effective natural ventilation and have considerable depth, which complicates their use as public spaces in peacetime. However, the application of passive ventilation technologies can create effective airflow channels within these structures, significantly enhancing ventilation efficiency and thus improving the overall thermal comfort level. For this study, air age, along with average wind speed, temperature, and relative humidity as stipulated by the "Requirements for Environmental Sanitation of Civil Air Defense Works during Peacetime Use" (GBT 17216-2012), were selected as evaluation metrics. This paper compares the ventilation effectiveness between single ventilation shafts and multiple ventilation shafts under positive and negative pressure conditions in underground civil defense structures. The results indicate that negative pressure ventilation in multiple shaft configurations performs optimally across various ventilation approaches. Subsequently, the Response Surface Methodology (RSM) was utilized to further optimize the positioning of multiple ventilation shafts. The study examined the impact of three ventilation shaft locations on average wind speed, temperature, relative humidity, and air age, leading to an optimized design. Specifically, the optimal positions are 54.76 m for Shaft A, 51.45 m for Shaft B, and 79.85 m for Shaft C, achieving an average wind speed of 0.222 m/s, a temperature of 26 °C, a relative humidity reduction to 85.47%, and an average air age of 10.57 s. This research provides practical insights for the optimization of ventilation in underground civil defense facilities.

Scientific ReportsVol. 14(1)
China University of Mining and Technology (CN), Jiangsu Vocational Institute of Architectural Technology (CN), Jiangsu Provincial Architectural Design and Research Institute (China) (CN), Shanghai Tongji Urban Planning and Design Institute (CN), Yangzhou University (CN)
Sustainable cities and communities
Openalex Percentile: Top 34%
Underground infrastructure and sustainability
0.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.