A Double-Stranded Aptamer for Highly Sensitive Fluorescent Detection of Glutathione S-Transferases

Aptamer-based biosensors have been widely constructed and applied to detect diverse targets. Glutathione S-transferase (GST), a pivotal phase II metabolic enzyme, plays a critical role in biotransformation in vivo, and aberrant GST expression is associated with various health risks. Herein, aptamers targeting GST were systematically selected from a randomized single-stranded DNA (ssDNA) library of 79 nucleotides (nt) using a biotinylated GST-immobilized streptavidin agarose (SA) bead SELEX technology. Following rigorous screening across eight rounds, four aptamers with strikingly similar secondary structures emerged. Among these, Seq3 exhibited the highest affinity towards GST and was selected for further optimization. A semi-rational post-SELEX truncation strategy was then employed based on base composition analysis, secondary structure analysis and affinity assessment. This strategy enabled the systematic removal of redundant nucleotides in Seq3 without compromising its affinity, ultimately yielding a truncated aptamer, Seq3-3, which retains its specificity with a compact 39nt length. Building upon Seq3-3, a double-stranded fluorescent aptamer probe was ingeniously designed for the in vitro detection of GST. The detection mechanism hinges on the competitive displacement of the complementary chain from the probe, mediated by the target protein, leading to the separation of the antisense oligonucleotide from the double-stranded complex. This process triggers the restoration of the fluorescence signal, enabling sensitive detection, and the probe exhibits excellent response within a linear range of GST activity ranging from 0 to 1500 U/L. The results show that not only an efficient strategy for screening robust and practicable aptamers but also an ultrahighly sensitive detection platform for GST was established.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2024-10-03
DOI
https://doi.org/10.3390/bios14100476
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Double-Stranded Aptamer for Highly Sensitive Fluorescent Detection of Glutathione S-Transferases

Jiahao Zeng, Suping Li, Zhaofeng Li, Xiangxian Meng et al.
1 citations
Biosensors
Advanced biosensing and bioanalysis techniques
0.23
article

A Double-Stranded Aptamer for Highly Sensitive Fluorescent Detection of Glutathione S-Transferases

Jiahao Zeng, Suping Li, Zhaofeng Li, Xiangxian Meng, Mei Yang, Qiuping Guo, Xiaohong Wen, Suxia Bao, Chen Li, Wei Cui
article en
1 citations

Abstract

Aptamer-based biosensors have been widely constructed and applied to detect diverse targets. Glutathione S-transferase (GST), a pivotal phase II metabolic enzyme, plays a critical role in biotransformation in vivo, and aberrant GST expression is associated with various health risks. Herein, aptamers targeting GST were systematically selected from a randomized single-stranded DNA (ssDNA) library of 79 nucleotides (nt) using a biotinylated GST-immobilized streptavidin agarose (SA) bead SELEX technology. Following rigorous screening across eight rounds, four aptamers with strikingly similar secondary structures emerged. Among these, Seq3 exhibited the highest affinity towards GST and was selected for further optimization. A semi-rational post-SELEX truncation strategy was then employed based on base composition analysis, secondary structure analysis and affinity assessment. This strategy enabled the systematic removal of redundant nucleotides in Seq3 without compromising its affinity, ultimately yielding a truncated aptamer, Seq3-3, which retains its specificity with a compact 39nt length. Building upon Seq3-3, a double-stranded fluorescent aptamer probe was ingeniously designed for the in vitro detection of GST. The detection mechanism hinges on the competitive displacement of the complementary chain from the probe, mediated by the target protein, leading to the separation of the antisense oligonucleotide from the double-stranded complex. This process triggers the restoration of the fluorescence signal, enabling sensitive detection, and the probe exhibits excellent response within a linear range of GST activity ranging from 0 to 1500 U/L. The results show that not only an efficient strategy for screening robust and practicable aptamers but also an ultrahighly sensitive detection platform for GST was established.

BiosensorsVol. 14(10)
Hunan University (CN), State Key Laboratory of Chemobiosensing and Chemometrics (CN)
Life in Land
Openalex Percentile: Top 42%
Advanced biosensing and bioanalysis techniques
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.