Analytical Method Development And Validation Of Impurity Profile In Semaglutide

An accurate and precise analytical method was developed to profile the contaminants in semaglutide API.The HiQSil C18 column (250 mm 4.6 mm, 5 m) was employed to optimise the mobile phase for enhanced impurity separation at 35 C.The mobile phase had a 65:35 (v/v) ratio of water to methanol.The mobile phase was delivered at a rate of 1.0 mL/min.The chromatogram was seen at 230 nm, and the mobile phase was modified to enhance resolution.Between the LOQ level and 150%, a recovery rate of 90% for semaglutide was found.The correlation coefficient (r2) for semaglutide and its impurities I, II, and III was found to exceed 0.998.In the robustness study, it was found that the approach remained impervious to variations in method variance.The established method is suitable for routine analysis of semaglutide in the quality control laboratory due to its robustness, accuracy, precision, and linearity.

Authors

Publication Details

Journal
African Journal of Biomedical Research
Published
2024-09-30
DOI
https://doi.org/10.53555/ajbr.v27i3s.2254
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Method Development And Validation Of Impurity Profile In Semaglutide

Satish Shelke
African Journal of Biomedical Research
Analytical Methods in Pharmaceuticals
article

Analytical Method Development And Validation Of Impurity Profile In Semaglutide

Satish Shelke
article en

Abstract

An accurate and precise analytical method was developed to profile the contaminants in semaglutide API.The HiQSil C18 column (250 mm 4.6 mm, 5 m) was employed to optimise the mobile phase for enhanced impurity separation at 35 C.The mobile phase had a 65:35 (v/v) ratio of water to methanol.The mobile phase was delivered at a rate of 1.0 mL/min.The chromatogram was seen at 230 nm, and the mobile phase was modified to enhance resolution.Between the LOQ level and 150%, a recovery rate of 90% for semaglutide was found.The correlation coefficient (r2) for semaglutide and its impurities I, II, and III was found to exceed 0.998.In the robustness study, it was found that the approach remained impervious to variations in method variance.The established method is suitable for routine analysis of semaglutide in the quality control laboratory due to its robustness, accuracy, precision, and linearity.

African Journal of Biomedical Research
Openalex Percentile: Top 85%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.