Experimental study on mechanical behavior and countermeasures of mountain tunnels under strike-slip fault movement

In the seismic mountainous regions such as western China, it is usuallly inevitable to construct tunnels near active fault zones. Those fault-crossing tunnel structures can be extremely vulnerable during earthquakes. Extensive experimental studies have been conducted on the response of continuous mountain tunnels under reverse and normal fault movements, limited experimental investigations are available in the literatures on mountain tunnels with special structural measures crossing strike-slip faults. In this study, a new experimental facility for simulating the movement of strike-slip fault was developed, accounting for the spatial deformation characteristics of large active fault zones. Two groups of sandbox experiment were performed on the scaled tunnel models to investigate the evolution of ground deformation and surface rupture subjected to strike-slip fault motion and its impact on a water conveyance tunnel. The nonlinear response and damage mechanism of continuous tunnels and tunnels incorporated with specially designed articulated system were examined. The test results show that most of slip between stationary block and moving block occurred within the fault core, and significant surface ruptures are observed along the fault strike direction at the fault damage zone. The continuous tunnel undergoes significant shrinkage deformation and diagonal-shear failure near the slip surface and resulted in localized collapse of tunnel lining. The segments of articulated system tunnel suffer a significant horizontal deflection of about 5°, which results in opening and misalignment at the flexible joint. The width of the damaged zone of the articulated system tunnel is about 0.44 to 0.57 times that of the continuous tunnel. Compared to continuous tunnels, the articulated design significantly reduces the axial strain response of the tunnel lining, but increases the circumferential tensile strain at the tunnel crown and invert. It is concluded that articulated design provides an effective measure to reduce the extent of damage in mountain tunnel.

Authors

Institutions

Publication Details

Journal
Underground Space
Published
2024-10-03
DOI
https://doi.org/10.1016/j.undsp.2024.07.006
Citations
32
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
8.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on mechanical behavior and countermeasures of mountain tunnels under strike-slip fault movement

Hongru Wang, Zilan Zhong, Zhen Wang, Jingqi Huang et al.
32 citations
Underground Space
Geotechnical Engineering and Underground Structures
8.35
article

Experimental study on mechanical behavior and countermeasures of mountain tunnels under strike-slip fault movement

Hongru Wang, Zilan Zhong, Zhen Wang, Jingqi Huang, Mi Zhao, Xiuli Du
article en
32 citations

Abstract

In the seismic mountainous regions such as western China, it is usuallly inevitable to construct tunnels near active fault zones. Those fault-crossing tunnel structures can be extremely vulnerable during earthquakes. Extensive experimental studies have been conducted on the response of continuous mountain tunnels under reverse and normal fault movements, limited experimental investigations are available in the literatures on mountain tunnels with special structural measures crossing strike-slip faults. In this study, a new experimental facility for simulating the movement of strike-slip fault was developed, accounting for the spatial deformation characteristics of large active fault zones. Two groups of sandbox experiment were performed on the scaled tunnel models to investigate the evolution of ground deformation and surface rupture subjected to strike-slip fault motion and its impact on a water conveyance tunnel. The nonlinear response and damage mechanism of continuous tunnels and tunnels incorporated with specially designed articulated system were examined. The test results show that most of slip between stationary block and moving block occurred within the fault core, and significant surface ruptures are observed along the fault strike direction at the fault damage zone. The continuous tunnel undergoes significant shrinkage deformation and diagonal-shear failure near the slip surface and resulted in localized collapse of tunnel lining. The segments of articulated system tunnel suffer a significant horizontal deflection of about 5°, which results in opening and misalignment at the flexible joint. The width of the damaged zone of the articulated system tunnel is about 0.44 to 0.57 times that of the continuous tunnel. Compared to continuous tunnels, the articulated design significantly reduces the axial strain response of the tunnel lining, but increases the circumferential tensile strain at the tunnel crown and invert. It is concluded that articulated design provides an effective measure to reduce the extent of damage in mountain tunnel.

Underground SpaceVol. 21
Beijing University of Technology (CN), Tianjin Research Institute of Water Transport Engineering (CN), Ministry of Transport (CN), China Academy of Information and Communications Technology (CN), University of Science and Technology Beijing (CN)
Climate action
Openalex Percentile: Top 1%
Geotechnical Engineering and Underground Structures
8.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.