Multi-objective optimization of HESS control for optimal frequency regulation in a power system with RE penetration

• Multi-objective optimization uses change of frequency and ROCOF. • Simultaneously optimized VI-VSG-HESS reduced effectively small frequency fluctuation. • Simultaneously optimized VSG-HESS reduced frequency nadir the most effectively. • Independently optimized VSG-HESS produced a well-rounded performance. Concerns over fossil fuel emissions and their hazardous effects have led to a shift away from conventional power plants and focus more on the expansion of renewable energy sources. This shift has resulted in reduced inertia and resulted in poor frequency control within electrical power systems. Hybrid Energy Storage Systems (HESS) have been proposed as an effective solution to enhance frequency stability and address the reduced inertia issue. This research evaluates three distinct control models for HESS, Incorporating Supercapacitor Energy Storage (SCES) and Battery Energy Storage Systems (BESS). To optimize the control parameters with the best objectives, all possible sets of objectives with four different optimization algorithms are studied. The three control models considered for the HESS incorporate Virtual Synchronous Generator (VSG) or Virtual Inertia (VI) control with independent or simultaneous optimization of control parameters. The performances of the three control models are evaluated based on three test scenarios incorporating uncertainties, reduced inertia, and uniform and random load disturbances. The findings indicate that the Independently Optimized Virtual Synchronous Generator HESS (IO VSG-HESS) achieves the best settling time post-contingency but offers the least improvement in frequency nadir with an average of 0.31 %. Conversely, the Simultaneously Optimized Virtual Inertia And Virtual Synchronous Generator Controlled HESS (SO VI-VSG-HESS) excel in mitigating small frequency fluctuations with an average improvement in frequency standard deviation of 87.65 %. The Simultaneously Optimized Virtual Synchronous Generator Controlled HESS (SO VSG-HESS) provides the best frequency nadir, with an average improvement of 0.63 %, but with a slight increase in settling time.

Authors

Institutions

Publication Details

Journal
e-Prime - Advances in Electrical Engineering Electronics and Energy
Published
2024-10-03
DOI
https://doi.org/10.1016/j.prime.2024.100805
Citations
7
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-objective optimization of HESS control for optimal frequency regulation in a power system with RE penetration

Rodney H.G. Tan, N. Mithulananthan, Farah Adilah Jamaludin, Ousama M.T. Ajami et al.
7 citations
e-Prime - Advances in Electrical Engineering Electronics and Energy
Frequency Control in Power Systems
1.46
article

Multi-objective optimization of HESS control for optimal frequency regulation in a power system with RE penetration

Rodney H.G. Tan, N. Mithulananthan, Farah Adilah Jamaludin, Ousama M.T. Ajami, Adlan Bagus Pradana
article en
7 citations

Abstract

• Multi-objective optimization uses change of frequency and ROCOF. • Simultaneously optimized VI-VSG-HESS reduced effectively small frequency fluctuation. • Simultaneously optimized VSG-HESS reduced frequency nadir the most effectively. • Independently optimized VSG-HESS produced a well-rounded performance. Concerns over fossil fuel emissions and their hazardous effects have led to a shift away from conventional power plants and focus more on the expansion of renewable energy sources. This shift has resulted in reduced inertia and resulted in poor frequency control within electrical power systems. Hybrid Energy Storage Systems (HESS) have been proposed as an effective solution to enhance frequency stability and address the reduced inertia issue. This research evaluates three distinct control models for HESS, Incorporating Supercapacitor Energy Storage (SCES) and Battery Energy Storage Systems (BESS). To optimize the control parameters with the best objectives, all possible sets of objectives with four different optimization algorithms are studied. The three control models considered for the HESS incorporate Virtual Synchronous Generator (VSG) or Virtual Inertia (VI) control with independent or simultaneous optimization of control parameters. The performances of the three control models are evaluated based on three test scenarios incorporating uncertainties, reduced inertia, and uniform and random load disturbances. The findings indicate that the Independently Optimized Virtual Synchronous Generator HESS (IO VSG-HESS) achieves the best settling time post-contingency but offers the least improvement in frequency nadir with an average of 0.31 %. Conversely, the Simultaneously Optimized Virtual Inertia And Virtual Synchronous Generator Controlled HESS (SO VI-VSG-HESS) excel in mitigating small frequency fluctuations with an average improvement in frequency standard deviation of 87.65 %. The Simultaneously Optimized Virtual Synchronous Generator Controlled HESS (SO VSG-HESS) provides the best frequency nadir, with an average improvement of 0.63 %, but with a slight increase in settling time.

e-Prime - Advances in Electrical Engineering Electronics and EnergyVol. 10
The University of Queensland (AU), UCSI University (MY)
Affordable and clean energy
Openalex Percentile: Top 17%
Frequency Control in Power Systems
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.