Anti-interference non-contact breathing frequency detection method based on wifi

With the rapid development of wireless sensing technologies, WiFi channel state information (CSI) has become a powerful tool for monitoring human vital signs, such as breathing and body movement. However, estimating respiration rate at rest is often constrained by body motion and non-target signal interference. In this study, we address this challenge by proposing an innovative joint oriented vector technique that accurately distinguishes between target and non-target signals and effectively eliminates the interference of non-target signals. An adaptive sliding window is used to compute the differential standard deviation of the CSI amplitude information, which is combined with a signal-to-noise ratio-optimised subcarrier selection strategy and a PW-Hampel filter to significantly suppress the interference caused by body motion and hardware noise to the respiratory monitoring signals, and an improved peak detection algorithm is used to accurately identify peaks in the respiratory signals. The experimental results show that the proposed method achieves a high accuracy of 98.90% under body movement conditions, which significantly exceeds the level of existing technology.

Authors

Institutions

Publication Details

Published
2024-10-03
DOI
https://doi.org/10.1117/12.3048054
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anti-interference non-contact breathing frequency detection method based on wifi

Weidong Wang, Hui Pang, Heyu Pan
1 links
Non-Invasive Vital Sign Monitoring
article

Anti-interference non-contact breathing frequency detection method based on wifi

Weidong Wang, Hui Pang, Heyu Pan
article en

Abstract

With the rapid development of wireless sensing technologies, WiFi channel state information (CSI) has become a powerful tool for monitoring human vital signs, such as breathing and body movement. However, estimating respiration rate at rest is often constrained by body motion and non-target signal interference. In this study, we address this challenge by proposing an innovative joint oriented vector technique that accurately distinguishes between target and non-target signals and effectively eliminates the interference of non-target signals. An adaptive sliding window is used to compute the differential standard deviation of the CSI amplitude information, which is combined with a signal-to-noise ratio-optimised subcarrier selection strategy and a PW-Hampel filter to significantly suppress the interference caused by body motion and hardware noise to the respiratory monitoring signals, and an improved peak detection algorithm is used to accurately identify peaks in the respiratory signals. The experimental results show that the proposed method achieves a high accuracy of 98.90% under body movement conditions, which significantly exceeds the level of existing technology.

North China Electric Power University (CN), Northeast Electric Power University (CN)
Openalex Percentile: Top 84%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.