Comparison of translation algorithms in determining maximum allowable CTV shifts for Real‐Time Gated Proton Therapy (RGPT) robustness evaluation in prostate cancers

Our results demonstrate that the simpler in-house algorithm performs equivalently to the realistic DIR algorithm when simulating CTV motion in prostate cancers. Furthermore, the in-house algorithm completes the robustness evaluation two orders of magnitude faster than the DIR algorithm. This significant reduction in evaluation time is crucial especially when preparatory time efficiency is of paramount importance in a busy clinic.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2024-10-03
DOI
https://doi.org/10.1002/acm2.14543
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.22

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of translation algorithms in determining maximum allowable CTV shifts for Real‐Time Gated Proton Therapy (RGPT) robustness evaluation in prostate cancers

Calvin Wei Yang Koh, James Cheow Lei Lee, James Kuan Huei Lee, Hong Qi Tan et al.
2 citations
Journal of Applied Clinical Medical Physics
Advanced Radiotherapy Techniques
1.22
article

Comparison of translation algorithms in determining maximum allowable CTV shifts for Real‐Time Gated Proton Therapy (RGPT) robustness evaluation in prostate cancers

Calvin Wei Yang Koh, James Cheow Lei Lee, James Kuan Huei Lee, Hong Qi Tan, Kah Seng Lew, Andrew A. Bettiol, Sung Yong Park
article en
2 citations

Abstract

Our results demonstrate that the simpler in-house algorithm performs equivalently to the realistic DIR algorithm when simulating CTV motion in prostate cancers. Furthermore, the in-house algorithm completes the robustness evaluation two orders of magnitude faster than the DIR algorithm. This significant reduction in evaluation time is crucial especially when preparatory time efficiency is of paramount importance in a busy clinic.

Journal of Applied Clinical Medical PhysicsVol. 26(1)
National University of Singapore (SG), Duke-NUS Medical School (SG), National Cancer Centre Singapore (SG)
Duke-NUS Medical School
Openalex Percentile: Top 21%
Advanced Radiotherapy Techniques
1.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.