Design and Development of a Coaxial Integrated Triaxial Fluxgate Sensor

Triaxial fluxgate sensors are widely used in vector magnetic measurement due to their excellent robustness and high resolution. Conventionally, they are assembled from three orthogonally placed single-axis fluxgates. However, the non-coincidence of the three single-axis fluxgate axis center points results in sensitive area non-uniformity of each axis and large crosstalk. To solve the problem of sensitive area non-uniformity and improve the accuracy of triaxial fluxgate in vector magnetic measurement, the impact of the center point position of a triaxial fluxgate on magnetic field measurement is investigated through finite element analysis. A coaxial integrated triaxial fluxgate sensor probe and its supporting circuits are proposed and fabricated. In addition, the geomagnetic field at three locations is measured by the proposed coaxial integrated triaxial fluxgate and the orthogonally placed single-axis fluxgates with equivalent specifications. The experiments show that as the distance among the axis center points of the three axes of the probe increases, the measured total magnetic flux density shows a trend of increasing first and then decreasing. The total magnetic flux density measurement error of the designed coaxial probe at all three locations is less than <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3~\mu $ </tex-math></inline-formula> T, which is better than the assembled triaxial fluxgate probe. The proposed coaxial triaxial fluxgate effectively overcomes the problems of large crosstalk and measurement point deviation caused by the non-uniform axis center points of traditional triaxial fluxgates.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Magnetics
Published
2024-10-03
DOI
https://doi.org/10.1109/tmag.2024.3472227
Citations
1
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Development of a Coaxial Integrated Triaxial Fluxgate Sensor

Zhengang Zhao, Chuan Luo, Yingjie Hou, Junjiang Shi
1 citations
IEEE Transactions on Magnetics
Magnetic Field Sensors Techniques
0.21
article

Design and Development of a Coaxial Integrated Triaxial Fluxgate Sensor

Zhengang Zhao, Chuan Luo, Yingjie Hou, Junjiang Shi
article en
1 citations

Abstract

Triaxial fluxgate sensors are widely used in vector magnetic measurement due to their excellent robustness and high resolution. Conventionally, they are assembled from three orthogonally placed single-axis fluxgates. However, the non-coincidence of the three single-axis fluxgate axis center points results in sensitive area non-uniformity of each axis and large crosstalk. To solve the problem of sensitive area non-uniformity and improve the accuracy of triaxial fluxgate in vector magnetic measurement, the impact of the center point position of a triaxial fluxgate on magnetic field measurement is investigated through finite element analysis. A coaxial integrated triaxial fluxgate sensor probe and its supporting circuits are proposed and fabricated. In addition, the geomagnetic field at three locations is measured by the proposed coaxial integrated triaxial fluxgate and the orthogonally placed single-axis fluxgates with equivalent specifications. The experiments show that as the distance among the axis center points of the three axes of the probe increases, the measured total magnetic flux density shows a trend of increasing first and then decreasing. The total magnetic flux density measurement error of the designed coaxial probe at all three locations is less than <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3~\mu $ </tex-math></inline-formula> T, which is better than the assembled triaxial fluxgate probe. The proposed coaxial triaxial fluxgate effectively overcomes the problems of large crosstalk and measurement point deviation caused by the non-uniform axis center points of traditional triaxial fluxgates.

IEEE Transactions on MagneticsVol. 60(12)
Kunming University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 48%
Magnetic Field Sensors Techniques
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Development of a Coaxial Integrated Triaxial Fluxgate Sensor — Zhengang Zhao, Chuan Luo, et al. · IEEE Transactions on Magnetics (2024) | TGRS Research Map | TGRS