A Case Report: Regenerative Biodegradable Chin Implant—A Viable Futuristic Option

Chin augmentation can dramatically transform a patient's appearance. Various techniques are in use, each with their specific problems and limitations. We present the first case report from the Indian subcontinent using a custom 3D-printed, bioresorbable polycaprolactone implant. We demonstrate, by appropriate imaging, the replacement of the implant at long-term (22 months) follow-up by patient's own autologous bone formation. An excellent aesthetic result was achieved. Relevant points of technique, as well as pertinent properties of the material, are discussed. This material has been used in neurosurgery and in the management of orbital fractures. Yet, worldwide, very few (3-4) cases of chin implant have been done using this material. We believe this to be a useful and sustainable material, offering several advantages, as set out in the case report.

Authors

Institutions

Publication Details

Journal
Indian Journal of Plastic Surgery
Published
2024-10-03
DOI
https://doi.org/10.1055/s-0044-1791686
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Case Report: Regenerative Biodegradable Chin Implant—A Viable Futuristic Option

Y. Jaiswal, Medha A Bhave
Indian Journal of Plastic Surgery
Facial Trauma and Fracture Management
article

A Case Report: Regenerative Biodegradable Chin Implant—A Viable Futuristic Option

Y. Jaiswal, Medha A Bhave
article en

Abstract

Chin augmentation can dramatically transform a patient's appearance. Various techniques are in use, each with their specific problems and limitations. We present the first case report from the Indian subcontinent using a custom 3D-printed, bioresorbable polycaprolactone implant. We demonstrate, by appropriate imaging, the replacement of the implant at long-term (22 months) follow-up by patient's own autologous bone formation. An excellent aesthetic result was achieved. Relevant points of technique, as well as pertinent properties of the material, are discussed. This material has been used in neurosurgery and in the management of orbital fractures. Yet, worldwide, very few (3-4) cases of chin implant have been done using this material. We believe this to be a useful and sustainable material, offering several advantages, as set out in the case report.

Indian Journal of Plastic SurgeryVol. 57(06)
Grant Medical College and Sir Jamshedjee Jeejeebhoy Group of Hospitals (IN), Government Medical College (IN)
Responsible consumption and production
Openalex Percentile: Top 68%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.