Towards an improved wind effect assessment for asbestos abatement: A methodology for reduced-scale experiments

During building renovation or demolition, asbestos fibers can be released which can contaminate the environment, leading to potential occupational health and public health concerns. Strict asbestos abatement procedures and regulations are in place to mitigate this risk, which involve sealing the worksite and depressurizing it relative to the outdoor environment (i.e., indoor pressure lower than the outdoor pressure) using mechanical ventilation. However, the depressurization of the containment can be breached by the effects of the wind. Hence, it is essential to identify which wind conditions are problematic and how to prevent their effects. To conduct corresponding laboratory measurements, it is first required to scale down the building and its containment zone including a working mechanical ventilation system. This paper presents an innovative methodology for conducting reduced-scale experiments on buildings equipped with mechanical ventilation systems for contaminant containment. The methodology, here explained in the context of asbestos abatement, could also be applied to any other type of particulate pollutant. The methodology of this research study includes the design of a mechanical ventilation system for depressurization; a method to scale down the building and the ventilation system for testing in a wind tunnel; and 3D steady Reynolds averaged Navier-Stokes (RANS) simulations for optimizing the positioning of the ventilation components. The methodology is applied for a single-zone building including its ventilation system, which is found to achieve the targeted indoor depressurization of -40 Pa, making it ready for wind tunnel tests.

Authors

Institutions

Publication Details

Journal
Journal of Environmental Management
Published
2024-10-03
DOI
https://doi.org/10.1016/j.jenvman.2024.122698
Citations
4
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.82

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards an improved wind effect assessment for asbestos abatement: A methodology for reduced-scale experiments

Stefanie Gillmeier, Bert Blocken, Romain Guichard, Alessio Ricci et al.
4 citations
Journal of Environmental Management
Wind and Air Flow Studies
0.82
article

Towards an improved wind effect assessment for asbestos abatement: A methodology for reduced-scale experiments

Stefanie Gillmeier, Bert Blocken, Romain Guichard, Alessio Ricci, A. K. R. Jayakumari
article en
4 citations

Abstract

During building renovation or demolition, asbestos fibers can be released which can contaminate the environment, leading to potential occupational health and public health concerns. Strict asbestos abatement procedures and regulations are in place to mitigate this risk, which involve sealing the worksite and depressurizing it relative to the outdoor environment (i.e., indoor pressure lower than the outdoor pressure) using mechanical ventilation. However, the depressurization of the containment can be breached by the effects of the wind. Hence, it is essential to identify which wind conditions are problematic and how to prevent their effects. To conduct corresponding laboratory measurements, it is first required to scale down the building and its containment zone including a working mechanical ventilation system. This paper presents an innovative methodology for conducting reduced-scale experiments on buildings equipped with mechanical ventilation systems for contaminant containment. The methodology, here explained in the context of asbestos abatement, could also be applied to any other type of particulate pollutant. The methodology of this research study includes the design of a mechanical ventilation system for depressurization; a method to scale down the building and the ventilation system for testing in a wind tunnel; and 3D steady Reynolds averaged Navier-Stokes (RANS) simulations for optimizing the positioning of the ventilation components. The methodology is applied for a single-zone building including its ventilation system, which is found to achieve the targeted indoor depressurization of -40 Pa, making it ready for wind tunnel tests.

Journal of Environmental ManagementVol. 370
Heriot-Watt University (GB), Eindhoven University of Technology (NL), Institut National de Recherche et de Sécurité (FR)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek, Institut National de Recherche et de Sécurité
Affordable and clean energy
Openalex Percentile: Top 30%
Wind and Air Flow Studies
0.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.