Using noninvasive imaging to assess manual lymphatic drainage on lymphatic/venous responses in a spaceflight analog

This retrospective case series (clinicaltrials.gov NCT06405282) used noninvasive imaging devices (NIID) to assess the effect of manual lymphatic drainage (MLD) on dermal/venous fluid distribution, perfusion, and temperature alterations of the head, neck, upper torso, and legs while in the 6-degree head-down tilt validated spaceflight analog. A lymphatic fluid scanner measured tissue dielectric constant levels. Near-infrared spectroscopy assessed perfusion, by measuring tissue oxygenation saturation. Long-wave infrared thermography measured tissue temperature gradients. Fifteen healthy, university students participated. NIID assessments were taken 1 minute after assuming the HDT position and then every 30 minutes, with MLD administered from 180 to 195 minutes. Subjects returned to the sitting position and were assessed at post-225 min NIID demonstrated significant changes from baseline (p < 0.01), although these changes at areas of interest varied. MLD had a reverse effect on all variables. NIID assessment supported the potential use of MLD to mitigate fluid shifts during a spaceflight analog.

Authors

Institutions

Publication Details

Journal
npj Microgravity
Published
2024-10-03
DOI
https://doi.org/10.1038/s41526-024-00429-w
Primary Topic
Spaceflight effects on biology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using noninvasive imaging to assess manual lymphatic drainage on lymphatic/venous responses in a spaceflight analog

Heather Barnhart, M. Mark Melin, Frank Aviles, Patrick C. Hardigan et al.
npj Microgravity
Spaceflight effects on biology
article

Using noninvasive imaging to assess manual lymphatic drainage on lymphatic/venous responses in a spaceflight analog

Heather Barnhart, M. Mark Melin, Frank Aviles, Patrick C. Hardigan, HARVEY NORMAN MAYROVITZ, Johanna Pannunzio, Nathan Sirkis, Kristen A. Eckert, Sabrina Ginsburg, Chantel Hubbard
article en

Abstract

This retrospective case series (clinicaltrials.gov NCT06405282) used noninvasive imaging devices (NIID) to assess the effect of manual lymphatic drainage (MLD) on dermal/venous fluid distribution, perfusion, and temperature alterations of the head, neck, upper torso, and legs while in the 6-degree head-down tilt validated spaceflight analog. A lymphatic fluid scanner measured tissue dielectric constant levels. Near-infrared spectroscopy assessed perfusion, by measuring tissue oxygenation saturation. Long-wave infrared thermography measured tissue temperature gradients. Fifteen healthy, university students participated. NIID assessments were taken 1 minute after assuming the HDT position and then every 30 minutes, with MLD administered from 180 to 195 minutes. Subjects returned to the sitting position and were assessed at post-225 min NIID demonstrated significant changes from baseline (p < 0.01), although these changes at areas of interest varied. MLD had a reverse effect on all variables. NIID assessment supported the potential use of MLD to mitigate fluid shifts during a spaceflight analog.

npj MicrogravityVol. 10(1)
Mayo Clinic (US), University of Miami (US), Nova Southeastern University (US), Mayo Clinic in Arizona (US), Strategic Solutions Consulting (United States) (US), National Hyperbaric Centre (GB)
Nova Southeastern University, University of California, San Diego
Zero hunger
Openalex Percentile: Top 76%
Spaceflight effects on biology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.