First results from a detector characterization lab for testing performance under space environmental conditions

A new setup for detector characterization consisting of a cryostat, tunable collimated light source, and versatile data acquisition system is currently being commissioned. The setup enables testing optical and infrared sensors in the 400 to 14000 nm wavelength range and the devices under test can be cooled to cryogenic temperatures of down to 50 K under vacuum condition. 32 spectral band passes with bandwidths of λ{ΔΛ ≥ 50 are available for spectral characterization, covering the full range from 400 to 14000 nm. The setup can be used to characterize responsivity, detectivity, noise equivalent temperature difference, dark current, linearity, dynamic range, well depth, and pixel response non-uniformity. We report on first results for the characterization of imaging sensors using Teledyne’s CCD47-20 as the device under test for which camera gain, linearity error, full well capacity, read noise, dark noise, and quantum efficiency have been determined. Furthermore, the performance of the light source and cryostat system will be discussed.

Authors

Publication Details

Published
2024-10-03
DOI
https://doi.org/10.1117/12.3027626
Primary Topic
Radioactive Decay and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First results from a detector characterization lab for testing performance under space environmental conditions

H. Rauer, Jan Binger, J. Knollenberg, Matthias Grott et al.
Radioactive Decay and Measurement Techniques
article

First results from a detector characterization lab for testing performance under space environmental conditions

H. Rauer, Jan Binger, J. Knollenberg, Matthias Grott, H. Michaelis, J. Helbert, Thomas Behnke, Christian Althaus, David Wolter
article en

Abstract

A new setup for detector characterization consisting of a cryostat, tunable collimated light source, and versatile data acquisition system is currently being commissioned. The setup enables testing optical and infrared sensors in the 400 to 14000 nm wavelength range and the devices under test can be cooled to cryogenic temperatures of down to 50 K under vacuum condition. 32 spectral band passes with bandwidths of λ{ΔΛ ≥ 50 are available for spectral characterization, covering the full range from 400 to 14000 nm. The setup can be used to characterize responsivity, detectivity, noise equivalent temperature difference, dark current, linearity, dynamic range, well depth, and pixel response non-uniformity. We report on first results for the characterization of imaging sensors using Teledyne’s CCD47-20 as the device under test for which camera gain, linearity error, full well capacity, read noise, dark noise, and quantum efficiency have been determined. Furthermore, the performance of the light source and cryostat system will be discussed.

Openalex Percentile: Top 75%
Radioactive Decay and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.