Development of a method to use standard hospital gamma cameras as triage whole body monitors in UK emergencies

This paper outlines the process by which a medical gamma camera can be utilised to support assessment of internal radionuclides for the public. While hospital based gamma cameras are able to detect photopeaks, they are often limited to an energy range of 40-540 keV. However, radionuclides with photopeak energies above 540 keV can still be detected as the partial collection of photon energy increases the count rate at lower energies. By combining extensive mathematical modelling with empirical calibration of multiple gamma cameras it is possible to develop a linear correlation between the efficiency of counting point sources and the overall counting efficiency for the camera. Once established, a simple protocol can be used to characterise any gamma camera, using optimal system settings, and hence generate a system efficiency with sufficient accuracy to allow the camera to be used in a triage process to committed effective doses of 2 mSv.&#xD.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2024-10-03
DOI
https://doi.org/10.1088/1361-6498/ad82f5
Citations
2
Primary Topic
Autopsy Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a method to use standard hospital gamma cameras as triage whole body monitors in UK emergencies

Lara Bonney, Daniel R. McGowan, Rachael Clitheroe, Julie Scott et al.
2 citations
Journal of Radiological Protection
Autopsy Techniques and Outcomes
0.81
article

Development of a method to use standard hospital gamma cameras as triage whole body monitors in UK emergencies

Lara Bonney, Daniel R. McGowan, Rachael Clitheroe, Julie Scott, Matthew Simpson
article en
2 citations

Abstract

This paper outlines the process by which a medical gamma camera can be utilised to support assessment of internal radionuclides for the public. While hospital based gamma cameras are able to detect photopeaks, they are often limited to an energy range of 40-540 keV. However, radionuclides with photopeak energies above 540 keV can still be detected as the partial collection of photon energy increases the count rate at lower energies. By combining extensive mathematical modelling with empirical calibration of multiple gamma cameras it is possible to develop a linear correlation between the efficiency of counting point sources and the overall counting efficiency for the camera. Once established, a simple protocol can be used to characterise any gamma camera, using optimal system settings, and hence generate a system efficiency with sufficient accuracy to allow the camera to be used in a triage process to committed effective doses of 2 mSv.&#xD.

Journal of Radiological ProtectionVol. 44(4)
Department of Health and Social Care (GB), Oxford University Hospitals NHS Trust (GB)
Openalex Percentile: Top 25%
Autopsy Techniques and Outcomes
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of a method to use standard hospital gamma cameras as triage whole body monitors in UK emergencies — Lara Bonney, Daniel R. McGowan, et al. · Journal of Radiological Protection (2024) | TGRS Research Map | TGRS