A dynamic approach for MR T2-weighted pelvic imaging

<i>Objective</i>. T2-weighted 2D fast spin echo sequence serves as the standard sequence in clinical pelvic MR imaging protocols. However, motion artifacts and blurring caused by peristalsis present significant challenges. Patient preparation such as administering antiperistaltic agents is often required before examination to reduce artifacts, which discomfort the patients. This work introduce a novel dynamic approach for T2 weighted pelvic imaging to address peristalsis-induced motion issue without any patient preparation.<i>Approach</i>. A rapid dynamic data acquisition strategy with complementary sampling trajectory is designed to enable highly undersampled motion-resistant data sampling, and an unrolling method based on deep equilibrium model is leveraged to reconstruct images from the dynamic sampled k-space data. Moreover, the fix-point convergence of the equilibrium model ensures the stability of the reconstruction. The high acceleration factor in each temporal phase, which is much higher than that in traditional static imaging, has the potential to effectively freeze pelvic motion, thereby transforming the imaging problem from conventional motion prevention or removal to motion reconstruction.<i>Main results</i>. Experiments on both retrospective and prospective data have demonstrated the superior performance of the proposed dynamic approach in reducing motion artifacts and accurately depicting structural details compared to standard static imaging.<i>Significance</i>. The proposed dynamic approach effectively captures motion states through dynamic data acquisition and deep learning-based reconstruction, addressing motion-related challenges in pelvic imaging.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-10-03
DOI
https://doi.org/10.1088/1361-6560/ad8335
Citations
2
Primary Topic
MRI in cancer diagnosis
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A dynamic approach for MR T2-weighted pelvic imaging

Yu Fu, Huimao Zhang, Zhuo‐Xu Cui, Guobin Li et al.
2 citations
Physics in Medicine and Biology
MRI in cancer diagnosis
0.81
article

A dynamic approach for MR T2-weighted pelvic imaging

Yu Fu, Huimao Zhang, Zhuo‐Xu Cui, Guobin Li, Zhenkui Wang, Naijia Liu, Qingneng Li, Jing Cheng, Dong Liang, Jun Yang
article en
2 citations

Abstract

<i>Objective</i>. T2-weighted 2D fast spin echo sequence serves as the standard sequence in clinical pelvic MR imaging protocols. However, motion artifacts and blurring caused by peristalsis present significant challenges. Patient preparation such as administering antiperistaltic agents is often required before examination to reduce artifacts, which discomfort the patients. This work introduce a novel dynamic approach for T2 weighted pelvic imaging to address peristalsis-induced motion issue without any patient preparation.<i>Approach</i>. A rapid dynamic data acquisition strategy with complementary sampling trajectory is designed to enable highly undersampled motion-resistant data sampling, and an unrolling method based on deep equilibrium model is leveraged to reconstruct images from the dynamic sampled k-space data. Moreover, the fix-point convergence of the equilibrium model ensures the stability of the reconstruction. The high acceleration factor in each temporal phase, which is much higher than that in traditional static imaging, has the potential to effectively freeze pelvic motion, thereby transforming the imaging problem from conventional motion prevention or removal to motion reconstruction.<i>Main results</i>. Experiments on both retrospective and prospective data have demonstrated the superior performance of the proposed dynamic approach in reducing motion artifacts and accurately depicting structural details compared to standard static imaging.<i>Significance</i>. The proposed dynamic approach effectively captures motion states through dynamic data acquisition and deep learning-based reconstruction, addressing motion-related challenges in pelvic imaging.

Physics in Medicine and BiologyVol. 69(20)
Shenzhen University (CN), Jilin University (CN), Chinese Academy of Sciences (CN), Academy of Mathematics and Systems Science (CN), First Hospital of Jilin University (CN), United Imaging Healthcare (China) (CN), Shenzhen Institutes of Advanced Technology (CN)
National Natural Science Foundation of China, Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province
Openalex Percentile: Top 25%
MRI in cancer diagnosis
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.