Magneto-acousto-electrical tomography based on frequency response compensated linearly frequency-modulated signal stimulation

<i>Objective</i>. In magneto-acousto-electrical tomography (MAET), linearly frequency-modulated (LFM) signal stimulation uses much lower peak voltage than the spike pulse stimulation, lengthening the operation life of the transducer. However, due to the uneven frequency responses of the transducer, the low-noise amplifier (LNA), and the bandpass filter (BPF), MAET using LFM signal stimulation suffers from longitudinal resolution loss. In this paper, frequency response compensated linearly frequency-modulated (FRC-LFM) signal stimulation is investigated to resolve the problem.<i>Approach</i>. The physical model of measurement of the frequency responses of the transducer and the cascading module of the detection electrodes, the LNA, and the BPF is constructed. The frequency responses are approximated by fitting a curve to the measurement data. The frequency response compensation function is set to the reciprocal of the product of the frequency responses. The digital FRC-LFM signal is generated in MATLAB and converted to analog signal through an arbitrary waveform generator. Two groups of MAET experiments are designed to confirm the performance of the FRC-LFM signal stimulation. Pure agar phantom with rectangular through-holes and agar phantom with pork tissue inclusion serve as the samples.<i>Main results</i>. The pulse-compressed magneto-acousto-electrical signal obtained using FRC-LFM stimulation has narrower main-lobe than that obtained using LFM excitation, although the signal to noise pulse interference ratio of the former is little lower than that of the latter, which is due to the limitation of the power amplifier. FRC-LFM also proves to be an effective method to utilize the frequency outside the working band of the transducer in MAET.<i>Significance</i>. The method in this study compensates for the longitudinal resolution loss due to the uneven frequency responses. Combining with high-capability power amplifier and high-performance LNA, the MAET using FRC-LFM signal stimulation can potentially achieve high longitudinal resolution and high sensitivity, advancing MAET toward the clinical application.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-10-02
DOI
https://doi.org/10.1088/1361-6560/ad8296
Citations
2
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magneto-acousto-electrical tomography based on frequency response compensated linearly frequency-modulated signal stimulation

Kebin Jia, Meijia Li, Zhishen Sun, Jianfei Wang
2 citations
Physics in Medicine and Biology
Electrical and Bioimpedance Tomography
0.42
article

Magneto-acousto-electrical tomography based on frequency response compensated linearly frequency-modulated signal stimulation

Kebin Jia, Meijia Li, Zhishen Sun, Jianfei Wang
article en
2 citations

Abstract

<i>Objective</i>. In magneto-acousto-electrical tomography (MAET), linearly frequency-modulated (LFM) signal stimulation uses much lower peak voltage than the spike pulse stimulation, lengthening the operation life of the transducer. However, due to the uneven frequency responses of the transducer, the low-noise amplifier (LNA), and the bandpass filter (BPF), MAET using LFM signal stimulation suffers from longitudinal resolution loss. In this paper, frequency response compensated linearly frequency-modulated (FRC-LFM) signal stimulation is investigated to resolve the problem.<i>Approach</i>. The physical model of measurement of the frequency responses of the transducer and the cascading module of the detection electrodes, the LNA, and the BPF is constructed. The frequency responses are approximated by fitting a curve to the measurement data. The frequency response compensation function is set to the reciprocal of the product of the frequency responses. The digital FRC-LFM signal is generated in MATLAB and converted to analog signal through an arbitrary waveform generator. Two groups of MAET experiments are designed to confirm the performance of the FRC-LFM signal stimulation. Pure agar phantom with rectangular through-holes and agar phantom with pork tissue inclusion serve as the samples.<i>Main results</i>. The pulse-compressed magneto-acousto-electrical signal obtained using FRC-LFM stimulation has narrower main-lobe than that obtained using LFM excitation, although the signal to noise pulse interference ratio of the former is little lower than that of the latter, which is due to the limitation of the power amplifier. FRC-LFM also proves to be an effective method to utilize the frequency outside the working band of the transducer in MAET.<i>Significance</i>. The method in this study compensates for the longitudinal resolution loss due to the uneven frequency responses. Combining with high-capability power amplifier and high-performance LNA, the MAET using FRC-LFM signal stimulation can potentially achieve high longitudinal resolution and high sensitivity, advancing MAET toward the clinical application.

Physics in Medicine and BiologyVol. 69(21)
Beijing University of Technology (CN), Beijing Information Science & Technology University (CN)
Beijing Municipal Natural Science Foundation, Yalong River Joint Fund
Openalex Percentile: Top 38%
Electrical and Bioimpedance Tomography
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.