The Right Ventricular-Arterial Compliance Index: A Novel Hemodynamic Marker to Predict Right Heart Failure Following Left Ventricular Assist Device

The development of right heart failure (RHF) in patients with advanced heart failure following left ventricular assist device (LVAD) implantation remains difficult to predict. We proposed a novel composite hemodynamic index-the right ventricular-arterial compliance index (RVACi), derived from pulmonary artery pulse pressure (PAPP), ejection time (ET), heart rate (HR), and cardiac output (CO), with and expressed as mm Hg·s/L. We then conducted a retrospective, single-center analysis comparing the predictive value of RVACi for the development of RHF or unplanned right ventricular (RV) mechanical circulatory support following LVAD implantation against existing hemodynamic indices. One hundred patients were enrolled after screening 232 patients over a 10 year period, with 74 patients having complete hemodynamic data for RVACi calculation. There was good correlation between pulmonary arterial capacitance ( R ² = 0.48) and pulmonary vascular resistance ( R ² = 0.63) with RVACi, but not RV stroke work index or pulmonary artery pulsatility index. Reduced baseline RVACi (52 ± 23 vs . 92 ± 55 mm Hg·s/L; p = 0.02) was the strongest hemodynamic predictor of unplanned RV mechanical circulatory support requirement in patients following LVAD insertion. Composite pulsatile hemodynamic indices including RVACi may provide additional insight over existing hemodynamic indices for the prediction of RHF and need for RV mechanical circulatory support.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2024-10-03
DOI
https://doi.org/10.1097/mat.0000000000002280
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Right Ventricular-Arterial Compliance Index: A Novel Hemodynamic Marker to Predict Right Heart Failure Following Left Ventricular Assist Device

K. Muthiah, Audrey Adji, Sumita Barua, David W.M. Muller et al.
ASAIO Journal
Mechanical Circulatory Support Devices
article

The Right Ventricular-Arterial Compliance Index: A Novel Hemodynamic Marker to Predict Right Heart Failure Following Left Ventricular Assist Device

K. Muthiah, Audrey Adji, Sumita Barua, David W.M. Muller, S. Hungerford, K. Kearney, Ning Song, Christopher S. Hayward
article en

Abstract

The development of right heart failure (RHF) in patients with advanced heart failure following left ventricular assist device (LVAD) implantation remains difficult to predict. We proposed a novel composite hemodynamic index-the right ventricular-arterial compliance index (RVACi), derived from pulmonary artery pulse pressure (PAPP), ejection time (ET), heart rate (HR), and cardiac output (CO), with and expressed as mm Hg·s/L. We then conducted a retrospective, single-center analysis comparing the predictive value of RVACi for the development of RHF or unplanned right ventricular (RV) mechanical circulatory support following LVAD implantation against existing hemodynamic indices. One hundred patients were enrolled after screening 232 patients over a 10 year period, with 74 patients having complete hemodynamic data for RVACi calculation. There was good correlation between pulmonary arterial capacitance ( R ² = 0.48) and pulmonary vascular resistance ( R ² = 0.63) with RVACi, but not RV stroke work index or pulmonary artery pulsatility index. Reduced baseline RVACi (52 ± 23 vs . 92 ± 55 mm Hg·s/L; p = 0.02) was the strongest hemodynamic predictor of unplanned RV mechanical circulatory support requirement in patients following LVAD insertion. Composite pulsatile hemodynamic indices including RVACi may provide additional insight over existing hemodynamic indices for the prediction of RHF and need for RV mechanical circulatory support.

ASAIO JournalVol. 71(2)
Victor Chang Cardiac Research Institute (AU), Royal North Shore Hospital (AU), UNSW Sydney (AU), St Vincent's Hospital Sydney (AU), Macquarie University (AU)
Good health and well-being
Openalex Percentile: Top 84%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies