Simulation of a capillary tube, fibre dual-readout calorimeter in DD4hep

Over the past years the dual-readout method for calorimetry, which exploits complementary information from Scintillation and Cherenkov channels, has emerged as candidate to fulfil the requirements for precision physics at future circular lepton colliders. While the dual-readout approach has been tested experimentally quite extensively, this type of calorimeter has never been used in an experiment at a collider. In recent years dedicated studies in simulation have investigated various detector geometries based on a fibre dual-readout calorimeter. One variation of the geometry, relying on capillary tubes, promises easy assembly with excellent geometrical accuracy at a moderate cost. In these proceedings, we present the status and latest results from a full 4 π detector geometry simulation in DD4hep. The simulation is used to estimate the performance of a dual-readout calorimeter for single electromagnetic and hadronic particles. The results for the dual-readout technique show an improvement in energy resolution for both electromagnetic and hadronic showers, with respect to single channel measurements.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2024-10-03
DOI
https://doi.org/10.1016/j.nima.2024.169940
Primary Topic
Muon and positron interactions and applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation of a capillary tube, fibre dual-readout calorimeter in DD4hep

A. Loeschcke Centeno
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Muon and positron interactions and applications
article

Simulation of a capillary tube, fibre dual-readout calorimeter in DD4hep

A. Loeschcke Centeno
article en

Abstract

Over the past years the dual-readout method for calorimetry, which exploits complementary information from Scintillation and Cherenkov channels, has emerged as candidate to fulfil the requirements for precision physics at future circular lepton colliders. While the dual-readout approach has been tested experimentally quite extensively, this type of calorimeter has never been used in an experiment at a collider. In recent years dedicated studies in simulation have investigated various detector geometries based on a fibre dual-readout calorimeter. One variation of the geometry, relying on capillary tubes, promises easy assembly with excellent geometrical accuracy at a moderate cost. In these proceedings, we present the status and latest results from a full 4 π detector geometry simulation in DD4hep. The simulation is used to estimate the performance of a dual-readout calorimeter for single electromagnetic and hadronic particles. The results for the dual-readout technique show an improvement in energy resolution for both electromagnetic and hadronic showers, with respect to single channel measurements.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1069
University of Sussex (GB)
European Commission, Horizon 2020 Framework Programme, HORIZON EUROPE Framework Programme
Affordable and clean energy
Openalex Percentile: Top 82%
Muon and positron interactions and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.