Clinical Evaluation of Stability of Short Deep Threaded Dental Implant During Early Healing Period: A Prospective Controlled Clinical Trial

Objectives: To assess the initial stability of short, deep-threaded dental implants placed in the posterior mandible and to determine the influence of deep-thread design on implant stability during early healing. Methods: Twenty short, deep-threaded implants were placed in the posterior mandibular region of ten patients. Insertion torque value (ITV) was recorded at implant placement. Implant stability quotient (ISQ) was measured immediately post-surgery and at weeks 2, 3, 4, and 5. Results: No significant difference in ITV was observed between short and standard implants. ISQ values did not significantly differ between implant types across the evaluation period (F = 1.17, p = 0.3). Conclusion; Short, deep-threaded implants demonstrate comparable primary stability to standard implants in the posterior mandible. These findings support their use as a viable treatment option for patients with advanced alveolar ridge resorption

Authors

Publication Details

Journal
Medicine and Clinical Science
Published
2024-10-03
DOI
https://doi.org/10.33425/2690-5191.1125
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Evaluation of Stability of Short Deep Threaded Dental Implant During Early Healing Period: A Prospective Controlled Clinical Trial

Abdulwahab Ismail Alkholani, Nashwan Abdulwahab Alkhawlani, Yahia Abdullah Alhadi, Arhab Abdulwahab Noman
Medicine and Clinical Science
Dental Implant Techniques and Outcomes
article

Clinical Evaluation of Stability of Short Deep Threaded Dental Implant During Early Healing Period: A Prospective Controlled Clinical Trial

Abdulwahab Ismail Alkholani, Nashwan Abdulwahab Alkhawlani, Yahia Abdullah Alhadi, Arhab Abdulwahab Noman
article en

Abstract

Objectives: To assess the initial stability of short, deep-threaded dental implants placed in the posterior mandible and to determine the influence of deep-thread design on implant stability during early healing. Methods: Twenty short, deep-threaded implants were placed in the posterior mandibular region of ten patients. Insertion torque value (ITV) was recorded at implant placement. Implant stability quotient (ISQ) was measured immediately post-surgery and at weeks 2, 3, 4, and 5. Results: No significant difference in ITV was observed between short and standard implants. ISQ values did not significantly differ between implant types across the evaluation period (F = 1.17, p = 0.3). Conclusion; Short, deep-threaded implants demonstrate comparable primary stability to standard implants in the posterior mandible. These findings support their use as a viable treatment option for patients with advanced alveolar ridge resorption

Medicine and Clinical ScienceVol. 6(4)
Openalex Percentile: Top 75%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.